MANNING, ND —
OSHA Inspection: C & D OILFIELD SERVICES, INC.
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of C & D OILFIELD SERVICES, INC. in KOVASH 1-6H WELL SITE 19TH STREET & HIGHWAY 22, MANNING, ND 58642 (NAICS 213112). OSHA activity number 340207661.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C & D OILFIELD SERVICES, INC.
- Site address
- KOVASH 1-6H WELL SITE 19TH STREET & HIGHWAY 22
- City
- MANNING
- State
- ND
- ZIP
- 58642
- Mailing
- 4673 HIGHWAY 85 SOUTH, BELFIELD, ND 58622
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 13
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1000 B02
- Issued
- Jun 25, 2015
- Abate by
- Jul 13, 2015
- Penalty
- Initial $2,800 · Current $1,960 Reduced
1480
General-duty citation text
29 CFR 1910.1000(b)(2): Employee(s) were exposed to an airborne concentration of hydrogen sulfide listed in Table Z-2 in excess of the ceiling concentration of 20 ppm: (a) On or about January 15, 2015, for the employee that was fatally overcome by hydrogen sulfide gas while working on top of a tank battery at the well site identified as the Kovash 1-6H near Manning, ND.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.1200 H03 I
- Issued
- Jun 25, 2015
- Abate by
- Jul 13, 2015
- Penalty
- Initial $0 · Current $0
1480
General-duty citation text
29 CFR 1910.1200(h)(3)(i): The employer failed to provide effective methods and observations for use to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.): (a) On or about January 15, 2015, for the employee that was fatally overcome by hydrogen sulfide gas while working on top of a tank battery, with a 4-gas monitor that was not functioning properly, at the well site identified as the Kovash 1-6H near Manning, ND.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at C & D Oilfield Services, INC.
View C & D Oilfield Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340207661.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.