Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARANDAS ROOFING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ARANDAS ROOFING in 1147 COUNTRY CLUB ROAD, OAK HILL, WV 25901 (NAICS 238160). OSHA activity number 340208321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arandas Roofing — free Get an email when a new federal OSHA severe-injury report for Arandas Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
ARANDAS ROOFING
Site address
1147 COUNTRY CLUB ROAD
City
OAK HILL
State
WV
ZIP
25901
Mailing
180 WESTON ACRES ROAD, KANNAPOLIS, NC 28081
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  a.)  Arandas Roofing, 1147 Country Club Road, Oak Hill WV:  On or about 1/23/15, employees using the Dewalt circular saw being supplied power from an extension cord plugged into a 120 volt 15 amp receptacle were not protected with the use of ground fault circuit interrupters.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1600

1926.404 F06

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a.)  Arandas Roofing, 1147 Country Club Road, Oak Hill, WV:  On or about 01/23/15, the path to ground for the green extension cord used to supply power to the Dewalt circular saw was not permanent and continuous in that, it had a missing ground prong.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1600

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a.)  Arandas Roofing, 1147 Country Club Road, Oak Hill WV:  On or about 1/23/15, employees replacing a residential shingled roof were not protected from falling 14' to the ground.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $2000

View Arandas Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340208321.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.