Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEGENDARY FIELD SERVICES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LEGENDARY FIELD SERVICES, LLC in QEP 16-32B QUAD PAD NEAR MANDAREE, MANDAREE, ND 58757 (NAICS 213112). OSHA activity number 340211291.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Legendary Field Services, LLC — free Get an email when a new federal OSHA severe-injury report for Legendary Field Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
QEP 16-32B QUAD PAD NEAR MANDAREE
City
MANDAREE
State
ND
ZIP
58757
Mailing
120 REAGAN STREET, WATFORD CITY, ND 58854
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 9, 2015
Abate by
Jul 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:   (a) On or about January 13, 2015, for the two employees who sustained flash fire burns where lockout/tagout procedures were not used when changing out a heater treater tube at the QEP well site identified as QEP 16-32b Quad Pad near Mandaree, ND.
Recent events (1)
  • — Z (S) $0

1910.307 C

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 9, 2015
Abate by
Jul 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:   (a) On or about January 13, 2015, for the two employees who sustained flash fire burns when an electric impact wrench with extension cord was used to change out a heater treater tube at the QEP well site identified as QEP 16-32b Quad Pad near Mandaree, ND.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340211291.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.