OLATHE, KS —
OSHA Inspection: SPX COOLING TECHNOLOGIES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPX COOLING TECHNOLOGIES in 1200 W. MARLEY ROAD, OLATHE, KS 66061 (NAICS 333415). OSHA activity number 340213156.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPX COOLING TECHNOLOGIES
- Site address
- 1200 W. MARLEY ROAD
- City
- OLATHE
- State
- KS
- ZIP
- 66061
- Mailing
- 1200 W. MARLEY ROAD, OLATHE, KS 66061
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 243
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 A02
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $4,250 · Current $4,250
General-duty citation text
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: Employee(s) climbing a fixed ladder up to a ladder platform along the north wall of the mold / pulverizer area were exposed to a fall hazard of approximately 11 feet due to no swing gate being provided on the ladder platform.
Recent events (2)
- — I (S) $4250
- — Z (S) $4250
1910.23 C01
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: (a) Employee(s) working by or entering the compressor pit area in the maintenance department were exposed to a fall hazard of approximately 84 inches due to no railing being provided next to the compressor pit stairway. The missing railing was approximately 46 inches in length. (b) Employee(s) working on the separator platform along the north wall of the mold / pulverizer area were exposed to a fall hazard of approximately 11 feet due to no top rail being provided for the northeast corner section of the platform. The northeast corner section of the platform with the missing top rail was approximately 27 inches in length.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jun 30, 2015
- Abate by
- Aug 17, 2015
- Penalty
- Initial $3,400 · Current $3,400
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Employee(s) working / walking by the Magnum 500 Wiedemann machine in the Steel shop (Fab side) were exposed to struck by hazards due to no machine guarding being provided on the right side of the machine where the parts table moves either east to west or north to south, depending on the equipment programming. The right side of the machine had no guarding in place to prevent workers from being inadvertently struck by the parts table. (b) Employee(s) operating the hydraulic Scale Gaging press in the Steel shop (Fab side) were exposed to caught in / between hazards due to no machine guarding being provided for the press cylinder. The Scale Gaging press cylinder moves up and down during operation, this creates a pinch point for the operators hand / fingers.
Recent events (2)
- — I (S) $3400
- — Z (S) $3400
1910.304 G05
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $3,400 · Current $3,400
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) Employee(s) using a yellow extension cord to charge the JLG manlift model #E450AJ in the Mold area were exposed to electrical hazards due to no grounding pin on the plug end of the extension cord. (b) Employee(s) using a panel strip to power the computer and monitors for the Amada Vipros 368 King II machine in the JIT Fab department were exposed to electrical hazards due to no grounding pin on the power cord plug end of the panel strip.
Recent events (2)
- — I (S) $3400
- — Z (S) $3400
1910.305 B02 I
- Issued
- Jun 30, 2015
- Penalty
- Initial $25,000 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
Recent events (2)
- — I (S) $7000
- — Z (R) $25000
1910.303 F02
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Circuit breakers were not labeled inside the low voltage electrical panel box on the east wall behind the DX punch in Jit Fab. (b) Circuit breakers were not labeled inside the low voltage electrical panel box on column 7 in Jit Fab. (c) Circuit breakers were not labeled inside the 277 / 480 volt lighting electrical panel box on column 7 in Grid machine department.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SPX Cooling Technologies
View SPX Cooling Technologies's full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340213156.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.