LAUDERHILL, FL —
OSHA Inspection: DEANGELO DEVELOPMENT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEANGELO DEVELOPMENT, INC. in 1890 N STATE RD 7, LAUDERHILL, FL 33313 (NAICS 236220). OSHA activity number 340214246.
Where did this inspection happen?
- Establishment
- DEANGELO DEVELOPMENT, INC.
- Site address
- 1890 N STATE RD 7
- City
- LAUDERHILL
- State
- FL
- ZIP
- 33313
- Mailing
- 1816 NW 19TH STREET, FORT LAUDERDALE, FL 33311
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). a.) On or about January 28, 2015, at the above addressed job site, employees were exposed to a fall hazard of approximately 12 feet, while performing carpentry work on fabricated frame scaffolds that were not fully planked.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a.) On or about January 28, 2015, at the above addressed job site, employees were exposed to a scaffold displacement hazard while performing carpentry work on a fabricated frame scaffolds that did not have base plates and mud sills.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, stucture, personnel hoist, or similar surface was not used. End rails were used as a means of access. a.) On or about January 28, 2015, at the above addressed job site, employees were exposed to a fall hazard of approximately 12 feet, while performing carpentry work on a fabricated frame scaffold which was not equipped with access ladders.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a.) On or about January 28, 2015, at the above addressed job site, employees were exposed to a fall and scaffold displacement hazards while performing carpentry work on a fabricated frame scaffold that had not been inspected by a competent person that lacked planking, guardrails, base plates, mudsills, and access ladders.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a.) On or about January 28, 2015, at the above addressed job site, employees were exposed to a fall hazard of approximately 12 feet, while performing carpentry work on a fabricated frame scaffold that lacked guardrails without a means of conventional fall protection.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a.) On or about January 28, 2015, at the above addressed job site, the employer did not provide training to employees who had performed carpentry work from scaffolds that lacked guardrails and a means of conventional fall protection and were exposed to a fall hazard of approximately 12 feet.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340214246.