Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAECO FABRICATION, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MAECO FABRICATION, INC. in 12530 SAEGER RD., GRAND BAY, AL 36541 (NAICS 331210). OSHA activity number 340214659.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maeco Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Maeco Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12530 SAEGER RD.
City
GRAND BAY
State
AL
ZIP
36541
Mailing
12530 SAEGER RD., GRAND BAY, AL 36541
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
17
Ownership type
A

2 citations on file for this inspection.

1910.94 A05 IV

Other-than-serious 1 instance 1 exposed
Issued
Feb 11, 2015
Abate by
Feb 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.94(a)(5)(iv): For employees who use respirators required by this section, the employer must implement a respiratory protection program in accordance with 29 CFR 1910.134.   a) Blasting area; on or about January 29, 2015 and times prior, the employer did not implement a Respiratory Protection Program for those employees required to wear respirators.
Recent events (1)
  • — Z (O) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Feb 11, 2015
Abate by
Feb 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a) Blasting and painting area; on or about January 29, 2015 and times prior, the employer did not implement a Respiratory Protection Program for those employees required to wear respirators.
Recent events (1)