APPLETON, WI —
OSHA Inspection: GREAT NORTHERN CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GREAT NORTHERN CORPORATION in 395 STROEBE ROAD, APPLETON, WI 54914 (NAICS 322211). OSHA activity number 340217793.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREAT NORTHERN CORPORATION
- Site address
- 395 STROEBE ROAD
- City
- APPLETON
- State
- WI
- ZIP
- 54914
- Mailing
- P.O. BOX 939, APPLETON, WI 54914
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 60
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 A
- Issued
- Apr 6, 2015
- Abate by
- May 26, 2015
- Penalty
- Initial $6,300 · Current $6,300
Recent events (2)
- — I (S) $6300
- — Z (S) $6300
1910.132 D01
- Issued
- Apr 6, 2015
- Abate by
- May 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) On or about January 18, 2015, during routine preventative maintenance on the Compac Rotary Valve on top of the Balemaster, Model # 4075G-8, Serial #12316B, located in Plant B, the employer did not assess the workplace to determine hazards that necessitate the use of personal protective equipment for falls and struck by hazards approximately 4 feet 5 inches above the ground. b) On or about January 26, 2015, during servicing operations on the Flexo Emba 245 cm FFG/Diecut Prefeeder Quick Set, Machine #1415, located in Plant C, the employer did not assess the workplace to determine hazards that necessitate the use of personal protective equipment for falls and struck by hazards approximately 5 feet 5 inches above the ground. c) On or about January 26, 2015, during servicing operations on the AFP Machine On the Module Facer, located in Plant B, the employer did not assess the workplace to determine hazards that necessitate the use of personal protective equipment for falls and struck by hazards approximately 9 feet 3 inches above the ground. e) On or about January 26, 2015, during preventative maintenance operations on the Air Converting Corporation East blower Mezzanine, located in Plant B, the employer did not assess the workplace to determine hazards that necessitate the use of personal protective equipment for falls and struck by hazards approximately 13 feet 4 inches above the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Great Northern Corporation
View Great Northern Corporation's full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340217793.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.