NEWTON, WI —
OSHA Inspection: PINE RIVER PRE-PACK, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PINE RIVER PRE-PACK, INC. in 10134 PINE RIVER ROAD, NEWTON, WI 53063 (NAICS 311513). OSHA activity number 340219955.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PINE RIVER PRE-PACK, INC.
- Site address
- 10134 PINE RIVER ROAD
- City
- NEWTON
- State
- WI
- ZIP
- 53063
- Mailing
- 10134 PINE RIVER ROAD, NEWTON, WI 53063
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C01
- Issued
- Mar 3, 2015
- Abate by
- Apr 7, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 1/30/2015, Company's LOTO program did not include procedures on the use of tags with locks or include training of affected employees.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.178 L04 III
- Issued
- Mar 3, 2015
- Abate by
- Apr 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On or about 1/30/2015, The company's powered industrial truck program needed to be upgraded to include refresher training every three years.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 3, 2015
- Abate by
- Apr 7, 2015
- Penalty
- Initial $1,700 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 1/30/2015, the VER-TECH, Inc. Baler M-72 was not operating properly which allowed the compression head to lower when it was not in use and raise without the safety door shut in an automatic mode. b) On or about 2/2/2015, the Cup Packaging Machine had two nip points that needed guarding. One was for the sealer head and the second was for the lid feeder. c) On or about 2/2/2015, the Funnel Agitator was turning with the lid open, exposing employees to caught-in injuries.
Recent events (2)
- — I (S) $1190
- — Z (S) $1700
1910.219 I02
- Issued
- Mar 3, 2015
- Abate by
- Apr 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: a) On or about 2/2/2015, The vertical shaft coupling on the labeler in the cup packaging area was not guarded. b) On or about 2/2/2015, The horizontal shaft coupling on the labeler in the cup packaging area was not guarded. c) On or about 2/2/2015, The horizontal shaft coupling on the candy case conveyor was not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Mar 3, 2015
- Abate by
- Mar 11, 2015
- Penalty
- Initial $1,360 · Current $952 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about 1/30/2015, the electrical disconnects and circuit breaker cabinets were not labeled to indicate their purpose on the second floor of the candy production area.
Recent events (2)
- — I (S) $952
- — Z (S) $1360
1910.305 B01 I
- Issued
- Mar 3, 2015
- Abate by
- Mar 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) On or about 1/30/2015 there was a 240 volt Precision battery charger in the warehouse that did not have a grommet in the circuit breaker box to prevent abrasion to the wire that was going thru it.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Pine River Pre-Pack, INC.
View Pine River Pre-Pack, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340219955.