Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BENCHMARK METAL SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BENCHMARK METAL SERVICES, INC. in 155 SEABORN ROAD, PONDER, TX 76259 (NAICS 236220). OSHA activity number 340220557.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benchmark Metal Services, INC. — free Get an email when a new federal OSHA severe-injury report for Benchmark Metal Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
155 SEABORN ROAD
City
PONDER
State
TX
ZIP
76259
Mailing
155 SEABORN ROAD, PONDER, TX 76259
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.178 P01

Serious Gravity 1 1 instance 12 exposed
Issued
May 29, 2015
Abate by
Jun 19, 2015
Penalty
Initial $1,200 · Current $700 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):      At the facility, employees operated a Hyster fork lift that was missing the seatbelt exposing employees to being ejected from the seat during operation.
Recent events (2)
  • — I (S) $700
  • — Z (S) $1200

1910.254 D09 III

Serious Gravity 1 1 instance 1 exposed
Issued
May 29, 2015
Abate by
Jun 19, 2015
Penalty
Initial $1,200 · Current $700 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:     At the facility, employees operated a Miller CP 300 welding unit that had the insulation torn from the cable exposing the inner conductors, which created electrical shock hazards.
Recent events (2)
  • — I (S) $700
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340220557.