Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WANNER METAL WORX

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of WANNER METAL WORX in 3555 MAIN STREET, HILLIARD, OH 43026 (NAICS 236220). OSHA activity number 340220789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wanner Metal Worx — free Get an email when a new federal OSHA severe-injury report for Wanner Metal Worx is published. One employer, no account, unsubscribe in one click.
Establishment
WANNER METAL WORX
Site address
3555 MAIN STREET
City
HILLIARD
State
OH
ZIP
43026
Mailing
525 LONDON RD, DELAWARE, OH 43015
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
40
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 2 instances 2 exposed
Issued
May 19, 2015
Abate by
Sep 7, 2015
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a.  On January 29, 2015, at the construction site located at 3555 Main Street, Hilliard, Ohio, employees were working on a canopy approximately 11 feet in height without the use of fall protection, thereby exposed to a fall hazard.    b.  On January 30, 2015, at the construction site located at 3555 Main Street, Hilliard, Ohio, employees were working on a canopy approximately 11 feet in height without the use of fall protection, thereby exposed to a fall hazard.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1926.1053 B01

Serious Gravity 10 2 instances 1 exposed
Issued
May 19, 2015
Abate by
Jun 5, 2015
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a.  On January 29, 2015, at the construction site located at 3555 Main Street, Hilliard, Ohio, an extension ladder was used to access a canopy approximately 11 feet in height that was positioned so that the ladder side rails were not extended at least 3 feet past the canopy surface, thereby exposing employees to a fall hazard.  a.  On January 30, 2015, at the construction site located at 3555 Main Street, Hilliard, Ohio, an extension ladder was used to access a canopy approximately 11 feet in height that was positioned so that the ladder side rails were not extended at least 3 feet past the canopy surface, thereby exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

1926.1053 B16

Serious Gravity 10 1 instance 2 exposed
Issued
May 19, 2015
Abate by
Jun 30, 2015
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired.    a.  At the construction site located at 3555 Main Street, Hilliard, Ohio, employees used a fiberglass, 24 feet, Louisville ladder, Model FE 3224, with structural defects, including, a defective cleat that was bent, corroded and had an anti-slip pad than was not completely attached, thereby, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340220789.