NEW PHILADELPHIA, OH —
OSHA Inspection: LAUREN MANUFACTURING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LAUREN MANUFACTURING, LLC in 2228 REISER AVENUE, S.E., NEW PHILADELPHIA, OH 44663 (NAICS 326299). OSHA activity number 340221191.
Where did this inspection happen?
- Establishment
- LAUREN MANUFACTURING, LLC
- Site address
- 2228 REISER AVENUE, S.E.
- City
- NEW PHILADELPHIA
- State
- OH
- ZIP
- 44663
- Mailing
- 2228 REISER AVENUE, S.E., NEW PHILADELPHIA, OH 44663
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 275
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a. The lockout procedure for the HSP-001 hydraulic press did not contain specific procedural steps for shutting down, isolating, blocking, and securing the electrical and gravitational energy sources. b. The lockout procedure for the HSP-002 hydraulic press did not contain specific procedural steps for shutting down, isolating, blocking, and securing the electrical and gravitational energy sources. c. The lockout procedure for the HSP-003 hydraulic press did not contain specific procedural steps for shutting down, isolating, blocking, and securing the electrical and gravitational energy sources. d. The lockout procedure for the HSP-004 hydraulic press did not contain specific procedural steps for shutting down, isolating, blocking, and securing the electrical and gravitational energy sources.
Recent events (3)
- — F (S) $6000
- — C (S) $7000
- — Z (S) $7000
1910.147 D02
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. a. In the splice department, the employer does not require the hydraulic press HSP-002 to be locked out and de-energized during mold changes. b. In the splice department, the employer does not require the hydraulic press HSP-003 to be locked out and de-energized during mold changes.
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.147 D05 I
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. a. During the lockout of hydraulic press HSP-001, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe. b. During the lockout of hydraulic press HSP-002, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe. c. During the lockout of hydraulic press HSP-003, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe. d. During the lockout of hydraulic press HSP-004, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe.
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a. In the splice department, the employer did not provide lockout training for employees performing mold changes on the HSP-001, HSP-002, HSP-003, and HSP-004 hydraulic presses.
Recent events (3)
- — F (S) $6000
- — C (S) $7000
- — Z (S) $7000
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $70000.00 · Current $50000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a. In the splice department, the point of operation on hydraulic press HSP-002 was not adequately guarded, resulting in employee injuries. b. In the splice department, the point of operation on hydraulic press HSP-003 was not adequately guarded, resulting in employee injuries.
Recent events (3)
- — F (R) $50000
- — C (W) $70000
- — Z (W) $70000
1904.39 A02
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. a. On or about January 19, 2015, the employer did not report to OSHA an employee injury resulting in an in-patient hospitalization.
Recent events (3)
- — F (O) $1000
- — C (O) $7000
- — Z (O) $7000
More inspections in this industry (NAICS 326299)
AURORA, CO—2026-07-01 00:00:00
PRETRED
AURORA, CO—2026-07-01 00:00:00
PRETRED
CADILLAC, MI—2026-06-24 00:00:00
TOTAL ENERGIES HOLDING COMPANY DBA HUTCHINSON ANTIVIBRATION SYSTEMS INC
PASADENA, TX—2026-06-10 00:00:00
XPO LOGISTICS FREIGHT, INC.
BABBITT, MN—2026-05-28 00:00:00
111335 - BLACK IRON RUBBER COMPANY
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340221191.