OSHA Inspection: MID-STATE MACHINE SHOP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MID-STATE MACHINE SHOP, INC. in 109 SOUTH DRIVE, EAST DUBLIN, GA 31027 (NAICS 332710). OSHA activity number 340221555.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mid-State Machine Shop, INC. — free Get an email when a new federal OSHA severe-injury report for Mid-State Machine Shop, INC. is published. One employer, no account, unsubscribe in one click.
Site address
109 SOUTH DRIVE
City
EAST DUBLIN
State
GA
ZIP
31027
Mailing
109 SOUTH DRIVE, EAST DUBLIN, GA 31027
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
18
Ownership type
A

10 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a). Main Shop Area - On or about January 30, 2015, the chuck on the metal lathes used in the shop were not guarded, thus exposing employees to a struck-by hazard.
Recent events (1)
  • — Z (S) $1600

1910.253 B04 III

Serious Gravity 5 1 instance 13 exposed
Issued
Jul 6, 2015
Penalty
Initial $1,700 · Current $1,700
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  a). Main Shop Area - On or about January 30, 2015, there were two oxygen and two acetylene cylinders that were stored adjacent to each other, thus exposing employees to a fire hazard.
Recent events (1)
  • — Z (S) $1700

1910.305 B01 II

Serious Gravity 5 1 instance 13 exposed
Issued
Jul 6, 2015
Penalty
Initial $1,360 · Current $1,360
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  a). Main Shop Area - On or about and times prior to January 30, 2015, there were three unused openings inside the main electrical breaker box, thus exposing employees to a fire hazard.
Recent events (1)
  • — Z (S) $1360

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l).  a). Main Shop Area - On or about and times prior to January 30, 2015, the employer did not certify the training and evaluation of employees that a Hyster lift truck (model: H60FT).
Recent events (1)
  • — Z (O) $0

1910.178 P01

Other-than-serious 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition.  a). Main Shop Area - On or about and times prior to January 30, 2015, the horn was not functional on a Hyster lift truck (model: H60FT), thus exposing employees to struck-by hazards.
Recent events (1)
  • — Z (O) $0

1910.178 Q07

Other-than-serious 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service.  a). Main Shop Area - On or about January 30, 2015, a Hyster lift truck (model: H60FT) was not inspected prior to use, thus exposing employees to struck-by hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  a). Main Shop Area - On or about and times prior to January 30, 2015, the employer did not develop and implement a written hazard communication program for employees that used hazardous chemicals such as, but not limited to coolant, cutting oil, acetylene, oxygen, carbon dioxide, and propane, thus exposing employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 F06

Other-than-serious 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer did not ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked in accordance with (f)(6)(i) or (f)(6)(ii) of this section.  a). Main Shop Area - On or about and times prior to January 30, 2015, plastic spray bottles that contained coolant and a 55 gallon drum that contained oil were not labeled to identify their contents and the hazards associated with the products, thus exposing employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not maintain safety data sheets for each hazardous chemical in use.  a). Main Shop Area - On or about and times prior to January 30, 2015, the employer did not maintain safety data sheets for hazardous chemicals that were used to include, but not limited to, coolant, cutting oil, acetylene, oxygen, carbon dioxide, and propane, thus exposing employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 13 exposed
Issued
Jul 6, 2015
Abate by
Jul 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.  a). Main Shop Area - On or about and times prior to January 30, 2015, the employer's hazard communication training was ineffective in which the training did not cover the following: proper labeling of secondary containers, the location and information contained in safety data sheets, and proper storage of incompatibles, thus exposing employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340221555.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.