KENNESAW, GA ·
OSHA Inspection: KENNESAW DRYWALL & SUPPLY, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KENNESAW DRYWALL & SUPPLY, INC. in 2210 BURNT WOOD DRIVE, NW, KENNESAW, GA 30152 (NAICS 444190). OSHA activity number 340221571.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KENNESAW DRYWALL & SUPPLY, INC.
- Site address
- 2210 BURNT WOOD DRIVE, NW
- City
- KENNESAW
- State
- GA
- ZIP
- 30152
- Mailing
- P.O. BOX 56, MARBLE HILL, GA 30148
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 8
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.178 L02 II
- Issued
- Feb 10, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) The Warehouse - An employee was required to operate a forklift and the employer did not provide training to that employee regarding the forklift's safe operation.
Recent events (1)
- · Z (O) $0
1910.1200 E01
- Issued
- Feb 10, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) Faciility - An employee was required to work with chemicals such as, but not limited to, propane and diesel fuel and the employer did not develop a written Hazard Communication Program.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 444190)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340221571.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.