Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: KENNESAW DRYWALL & SUPPLY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KENNESAW DRYWALL & SUPPLY, INC. in 2210 BURNT WOOD DRIVE, NW, KENNESAW, GA 30152 (NAICS 444190). OSHA activity number 340221571.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kennesaw Drywall & Supply, INC. for free Get an email when a new federal OSHA severe-injury report for Kennesaw Drywall & Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2210 BURNT WOOD DRIVE, NW
City
KENNESAW
State
GA
ZIP
30152
Mailing
P.O. BOX 56, MARBLE HILL, GA 30148
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
8
Ownership type
Private (A)

2 citations on file for this inspection.

1910.178 L02 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.  a)  The Warehouse - An employee was required to operate a forklift and the employer did not provide training to that employee regarding the forklift's safe operation.
Recent events (1)
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a)  Faciility - An employee was required to work with chemicals such as, but not limited to, propane and diesel fuel and the employer did not develop a written Hazard Communication Program.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340221571.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.