Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOD SHOP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOD SHOP, INC. in 1783 E. 1500 RD., LAWRENCE, KS 66044 (NAICS 561730). OSHA activity number 340251131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SOD Shop, INC. — free Get an email when a new federal OSHA severe-injury report for SOD Shop, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SOD SHOP, INC.
Site address
1783 E. 1500 RD.
City
LAWRENCE
State
KS
ZIP
66044
Mailing
1783 E. 1500 RD., LAWRENCE, KS 66044
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
15
Ownership type
A

10 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  Employees working in the South Shed were exposed to a crushed-by hazard in that the upper or mezzanine floor of the tool crib, being utilized for tool and material storage, was not marked indicating the rated capacity of the floor.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.23 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.  Employees working in the South Shed were exposed to a fall hazard of 7 feet 10 inches to the concrete floor below.  Approximately 10 feet of the guard rail for the upper or mezzanine level of the tool crib was 34 inches vertical height from upper surface of top rail to floor and was not provided with a mid rail.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 F03

Serious Gravity 5 2 instances 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven - 7 feet or less above floors or ground were not enclosed:  Employees on the installation crew were exposed to injury from in-going nip point hazards in that the chain and sprockets, approximately 3 feet from ground level, on the sod rolling machines were not provided with guards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.253 B02 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  Employees working in the South Shed were exposed to injury from a projectile hazard.  One compressed gas cylinder of argon was stored without a valve cap to protect the valve from damage.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.253 B04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:  Employees working in the South Shed were exposed to injury from a fire/explosion hazard.  One compressed gas cylinder of oxygen was stored with one compressed gas cylinder of acetylene in the shop area.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.303 F02

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Employees working in the North Shed were exposed to electrical shock hazards in that the breakers in the electrical panel located in the southeast corner of the shop were not marked.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 G02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  Employees working in the North Shed were exposed to an electrical shock hazard due to exposed live parts of electrical equipment as follows:        a)  The extension cord that was run through the door to the outside of the building had broken insulation exposing the conductors.      b)  The electrical service panel, located in the southeast corner of the shop, was missing a circuit breaker exposing the live bus bar in the back of the panel box.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 G01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location:  Employees working in the North Shed were exposed to an electrical shock hazard.  The female end of the 110 VAC energized extension cord that was routed through the door was laying on the ground in mud, a wet location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where run through doorways, windows, or similar openings or where attached to building surfaces:  Employees were exposed to an electrical shock hazard in the following locations:      a)  At the North Shed where the 110 VAC extension cord was routed through the metal door to the outside of the building.      b)  In the North Shed where 110 VAC romex cable is zip tied to the metal structure of the building and providing power to outlets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 30, 2015
Abate by
May 14, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  Employees working in the south shed engaged in welding activities were exposed to electrical shock hazards in that the flexible cord supplying 220 VAC power to the Miller, Millermatic 251 welder was not equipped with strain relief.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

View SOD Shop, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340251131.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.