Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROMA RISTORANTE AND PIZZERIA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROMA RISTORANTE AND PIZZERIA in 25 UNION ST, SIDNEY, NY 13838 (NAICS 722511). OSHA activity number 340253475.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roma Ristorante and Pizzeria — free Get an email when a new federal OSHA severe-injury report for Roma Ristorante and Pizzeria is published. One employer, no account, unsubscribe in one click.
Site address
25 UNION ST
City
SIDNEY
State
NY
ZIP
13838
Mailing
25 UNION ST, SIDNEY, NY 13838
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722511
Employees
20
Ownership type
A

7 citations on file for this inspection.

1910.1200 E01

Other-than-serious 1 instance 20 exposed
Issued
Feb 19, 2015
Abate by
Mar 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met.     a) Location: 25 Union St, Sidney, NY, on or about 2/3/15: The employer did not have a written Hazard Communication Program in place.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1904.4 A

Other-than-serious 1 instance 20 exposed
Issued
Feb 19, 2015
Abate by
Mar 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1904.4(a):  Each employer required by this Part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness.  a) Location: 25 Union St, Sidney, NY, on or about 2/3/15: The employer did not keep records for injury and illnesses at this location.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 A02

Serious Gravity 5 1 instance 20 exposed
Issued
Feb 12, 2015
Abate by
Mar 5, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.22(a)(2): The floor of every workroom shall be maintained in a clean and, so far as possible, a dry condition.        a) Location: 25 Union St, Sidney, NY, on or about 2/3/15:  Floors in prep room/cooking area were found to be in extremely wet. This was due to a leaky roof that was dripping directly on to floors, food prep tables and shelving that stored food prep equipment.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.37 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 12, 2015
Abate by
Feb 23, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times.    a) Location: 25 Union St, Sidney, NY, on or about 2/3/15: Backroom prep area has an inoperable emergency light.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 12, 2015
Abate by
Feb 28, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a) Location: 25 Union St, Sidney, NY, on or about 2/3/15: The employer has not established a Energy Control Plan for employees who perform maintenance on electrical systems.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.303 B07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 12, 2015
Abate by
Feb 23, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.    a) Location: 25 Union St, Sidney, NY, on or about 2/3/15: Electrical panel C- has an open breaker slot located at slot 41.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.305 A02 IX

Serious Gravity 5 2 instances 5 exposed
Issued
Feb 12, 2015
Abate by
Feb 23, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard.    a) Location: 25 Union St, Sidney, NY, on or about 2/3/15: Walk in freezer had an unprotected light bulb located on the ceiling at an elevation of approxiamately 7 feet.    b) Location: 25 Union St, Sidney, NY, on or about 2/3/15: Walk in freezer had an unprotected broken light bulb approxiamately 6 feet in elevation on the door side wall.