ALBANY, NY —
OSHA Inspection: LYONS BUILDING & CONSULTING, LLC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of LYONS BUILDING & CONSULTING, LLC. in 315 NORTHERN BLVD. PHILIP LIVINGSTON MAGNET ACDEMY SENIOR APARTMENTS, ALBANY, NY 12210 (NAICS 238350). OSHA activity number 340261726.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LYONS BUILDING & CONSULTING, LLC.
- Site address
- 315 NORTHERN BLVD. PHILIP LIVINGSTON MAGNET ACDEMY SENIOR APARTMENTS
- City
- ALBANY
- State
- NY
- ZIP
- 12210
- Mailing
- P.O. BOX 437, VOORHEESVILLE, NY 12186
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.304 F
- Issued
- Feb 26, 2015
- Penalty
- Initial $1,360 · Current $950 Reduced
General-duty citation text
29 CFR 1926.304(f): All woodworking machinery did not meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery: (a) Third Story Floor Hallway - on or about January 29, 2105 - the DeWalt DW745 portable table saw was not equipped with anti-kickback dogs. Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or throw it back toward the operator. (b) Third Story Floor Hallway - on or about January 29, 2015 - the DeWalt DW745 portable table saw was not equipped with a magnetic anti-restart switch. Section 3.1.3(c) American National Standards Institute 01.1-1961, Safety code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): On applications where injury to the operator might result if motors were to restart after power failures, provisions were not made to prevent machines from automatically restarting upon restoration of power.
Recent events (2)
- — I (S) $950
- — Z (S) $1360
1926.304 I01
- Issued
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: (a) Third Story Floor Hallway - on or about January 29, 2105 - the DeWalt DW745 portable table saw was not equipped with a hood guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238350)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340261726.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.