Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRINITY STAINLESS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRINITY STAINLESS INC. in 1318 N. ASHLEY DRIVE STE 10, NIXA, MO 65714 (NAICS 331210). OSHA activity number 340261817.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trinity Stainless INC. — free Get an email when a new federal OSHA severe-injury report for Trinity Stainless INC. is published. One employer, no account, unsubscribe in one click.
Site address
1318 N. ASHLEY DRIVE STE 10
City
NIXA
State
MO
ZIP
65714
Mailing
1318 N. ASHLEY DRIVE STE 10, NIXA, MO 65714
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
19
Ownership type
A

3 citations on file for this inspection.

1910.212 A02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 11, 2015
Abate by
Mar 31, 2015
Penalty
Initial $1,700 · Current $0 Reduced
29 CFR 1910.212(a)(2)  Machine guarding was not  provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points and rotating parts in locations including, but not limited to:  On or about January 21, 2015 at the Trinity Stainless facility- employees in the plant were exposed to rotating parts of an unguarded metal/aluminum lathe.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1700

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 11, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:     On, or at dates prior to, January 21, 2015- employees were exposed to a struck by hazard from a Dayton Bench Grinder, in the Maintenance Shop, which had tongue guards that were improperly adjusted in excess of one-fourth inch.       Abatement certification for this item is not required:
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.303 G01 III

Serious Gravity 1 1 instance 19 exposed
Issued
Feb 11, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.303(g)(1)(iii): The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less.    ON OR ABOUT January 21, 2015 AT THE Trinity Stainless facility- There was not an adequate entrance to the electrical panel box as the entrance was only 15 inches wide.       Abatement verification for this item is not required.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

View Trinity Stainless INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340261817.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.