NIXA, MO —
OSHA Inspection: TRINITY STAINLESS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRINITY STAINLESS INC. in 1318 N. ASHLEY DRIVE STE 10, NIXA, MO 65714 (NAICS 331210). OSHA activity number 340261817.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRINITY STAINLESS INC.
- Site address
- 1318 N. ASHLEY DRIVE STE 10
- City
- NIXA
- State
- MO
- ZIP
- 65714
- Mailing
- 1318 N. ASHLEY DRIVE STE 10, NIXA, MO 65714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 19
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A02
- Issued
- Feb 11, 2015
- Abate by
- Mar 31, 2015
- Penalty
- Initial $1,700 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(2) Machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points and rotating parts in locations including, but not limited to: On or about January 21, 2015 at the Trinity Stainless facility- employees in the plant were exposed to rotating parts of an unguarded metal/aluminum lathe.
Recent events (2)
- — I (S) $0
- — Z (S) $1700
1910.215 B09
- Issued
- Feb 11, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On, or at dates prior to, January 21, 2015- employees were exposed to a struck by hazard from a Dayton Bench Grinder, in the Maintenance Shop, which had tongue guards that were improperly adjusted in excess of one-fourth inch. Abatement certification for this item is not required:
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.303 G01 III
- Issued
- Feb 11, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(iii): The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less. ON OR ABOUT January 21, 2015 AT THE Trinity Stainless facility- There was not an adequate entrance to the electrical panel box as the entrance was only 15 inches wide. Abatement verification for this item is not required.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
More inspections at Trinity Stainless INC.
View Trinity Stainless INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331210)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340261817.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.