Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FALLS STAMPING AND WELDING CO. INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FALLS STAMPING AND WELDING CO. INC. in 2900 VINCENT ST., CUYAHOGA FALLS, OH 44221 (NAICS 332119). OSHA activity number 340262492.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Falls Stamping and Welding CO. INC. — free Get an email when a new federal OSHA severe-injury report for Falls Stamping and Welding CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
2900 VINCENT ST.
City
CUYAHOGA FALLS
State
OH
ZIP
44221
Mailing
2900 VINCENT ST., CUYAHOGA FALLS, OH 44221
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332119
Employees
98
Ownership type
A

5 citations on file for this inspection.

1910.303 G01

Serious Gravity 1 2 instances 10 exposed
Issued
Jul 29, 2015
Abate by
Aug 8, 2015
Penalty
Initial $2,700 · Current $1,800 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:      On or about February 4, 2015, the employer failed to ensure that 480v electrical panels located in the welding department of the facility were provided with sufficient access and working space. The panels were blocked by and industrial fan, industrial welder, and miscellaneous equipment.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2700

1910.147 C04 II B

Repeat 1 instance 25 exposed
Issued
Jul 29, 2015
Abate by
Jan 8, 2016
Penalty
Initial $1,800 · Current $1,800
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    On or about February 4, 2015 the employer failed to ensure that the energy control procedures for the 150 ton Verson Bed 36x60 Press (#29) specifically outlined the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. The employer's energy control procedures did not identify all potential energy sources to include but not limited, gravity of the dies on mechanical power presses, and to ensure that die blocks are used for blocking/ securing the upper die.         The Falls Stamping and Welding Co. Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii)(b), which was contained in OSHA inspection number 769542, citation number 1, item number 1a and was affirmed as a final order on 04/22/2013, with respect to a workplace located at 1720 Fall Street, Cleveland, OH.
Recent events (2)
  • — I (R) $1800
  • — Z (R) $1800

1910.147 C04 II D

Repeat 1 instance 25 exposed
Issued
Jul 29, 2015
Abate by
Jan 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control    On or about February 4, 2015 the employer failed to ensure that machine specific procedures of the 150 ton Verson Bed 36x30 mechanical power press (#29) clearly and  specifically outlined the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. The employer's energy control procedure did not include enough specificity which included using die blocks to secure the upper arm and to include verification that the press was de-energized when other maintenance was conducted on the press(es).      The Falls Stamping and Welding Co. Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii)(b), which was contained in OSHA inspection number 769542, citation number 1, item number 1b and was affirmed as a final order on 04/22/2013, with respect to a workplace located at 1720 Fall Street, Cleveland, OH.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.147 C06 I

Repeat 1 instance 98 exposed
Issued
Jul 29, 2015
Abate by
Jan 8, 2016
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    On or about February 5, 2015, the employer failed to conducted a periodic inspection of the energy control procedures at least annually. Equipment and machinery within the facility includes but is not limited to, presses, grinders, straighteners, cut-off saws, and cranes. Potential hazardous energies include pneumatic, electrical, mechanical, hydraulic, and gravitational.    The Falls Stamping and Welding Co. Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 106894, citation number 1, item number 3 and was affirmed as a final order on 10/15/2012, with respect to a workplace located at 1720 Fall Street, Cleveland, OH.
Recent events (2)
  • — I (R) $0
  • — Z (R) $1800

1910.305 G01 IV A

Other-than-serious 1 instance 10 exposed
Issued
Jul 29, 2015
Abate by
Oct 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:      a)  On or about February 4, 2015, a flexible cord supplying 110v power from a receptacle to the welding fume hood in the welding department was used in lieu of permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Falls Stamping and Welding CO. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340262492.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.