Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: E.R. WAGNER MANUFACTURING COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of E.R. WAGNER MANUFACTURING COMPANY in 4611 N. 32ND STREET, MILWAUKEE, WI 53209 (NAICS 332510). OSHA activity number 340262898.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch E.R. Wagner Manufacturing Company — free Get an email when a new federal OSHA severe-injury report for E.R. Wagner Manufacturing Company is published. One employer, no account, unsubscribe in one click.
Site address
4611 N. 32ND STREET
City
MILWAUKEE
State
WI
ZIP
53209
Mailing
4611 N. 32ND STREET, MILWAUKEE, WI 53209
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332510
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.176 A

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 16, 2015
Abate by
Jul 6, 2015
Penalty
Initial $2,618 · Current $1,309 Reduced
29 CFR 1910.176(a): Where mechanical handling equipment was used, sufficient safe clearances were not allowed for aisles, at loading docks, through doorways or wherever turns or passage had to be made:    (a) The assembly area aisles were not maintained properly, to allow employees on forklifts to see around corners. This exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $1309
  • — Z (S) $2618

1910.303 G01

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 16, 2015
Abate by
Jun 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) The area in front of an electrical panel, in the assembly area, was not kept clear for servicing and/or maintenance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View E.R. Wagner Manufacturing Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340262898.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.