OSHA Inspection: MAIN STEEL POLISHING COMPANY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MAIN STEEL POLISHING COMPANY in 761 BEDFORD ST. NW, ATLANTA, GA 30318 (NAICS 332813). OSHA activity number 340327097.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Main Steel Polishing Company — free Get an email when a new federal OSHA severe-injury report for Main Steel Polishing Company is published. One employer, no account, unsubscribe in one click.
Site address
761 BEDFORD ST. NW
City
ATLANTA
State
GA
ZIP
30318
Mailing
761 BEDFORD ST. NW, ATLANTA, GA 30318
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
216
Ownership type
A

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2015
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    a.) Cut to length: The employees were exposed to a fall hazard of approximately 5 feet while exchanging out coils and walking within 1- 2 feet of an unguarded pit.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.37 A03

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 26, 2015
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    a.) Adjacent to the maintenance area: The employees were exposed to fire hazards as a stack of pallets were staged within 4 inches of the exit door and impeded the exit route.     b.) Outside the Exit Door to the Cut to Length Line: The employees were exposed to fire hazards when materials, such as but not limited to drums of chemicals, impeded the exit route.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.219 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 26, 2015
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    a.) Cut to Length: The employer exposed employees to amputation hazards when they were required to work within 1 feet of the unguarded sprocket that was 3 feet above the floor and operating at 700 RPM on the Mardel machine.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.305 A02 X

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 26, 2015
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage.    a.) Cut to Length Line: The employees were exposed to electrical/fire hazards when the flexible cord/cable from the coil flipper electrical panel was extended along the floor into the electrical circuit.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.305 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   a.) Coil/Sheet Polish Line: The employer exposed employees to electrical hazards while operating the coil equipment with a knockout missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  a.) Breezeway between the Coil/Sheet Polish Line: The employees were exposed to electrical hazards when the flexible cord/cable from the compactor extended through the wall and into an electrical panel within the Coil/Sheet Line area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 26, 2015
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    a.) Sheet/Coil Polish Line: The employees were exposed to chemical hazards when the employer permitted the employee to dispense acetone into a red container that was not labeled with the appropriate hazard warnings.    b.) Breezeway outside of the Cut to Length Exit Door: The employees were exposed to chemical hazards when the employer stored chemicals inside of seven 50 gallon drums that were not labeled with the appropriate hazard warnings.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.303 G01 II

Other-than-serious 4 instances 5 exposed
Issued
Jun 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:     a.) Breeze way between the Coil/Sheet Polish Line & the Cut to Length Line: The employees were exposed to an electrical hazard when the waste container blocked the compactor 480 volt electrical panel by 7 inches.   b.) Cut to Length Line: The employees were exposed to an electrical hazard when the motor blocked the Coil Flipper 480 volt electrical panel by 16 inches.    c.) Near Coil/Sheet Polish Line (by the Coil Polish filtration system): The employees were exposed to an electrical hazard when coil supplies blocked 480 volt electrical panel by 10 inches.   d.) Coil/Sheet Polish Bay: The employees were exposed to an electrical hazard when the coil material blocked the 480 volt electrical panel by 16 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1026 D02 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 26, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 0689

29 CFR 1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area:  a.) Coil/Sheet Polish Line: The employer exposed employees to respiratory hazards when they were required to weld stainless steel (contains Chromium IV) for the polishing process and failed to perform initial monitoring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0