LINCOLN, NE —
OSHA Inspection: REXNORD INDUSTRIES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REXNORD INDUSTRIES, LLC in 6040 FLETCHER AVE, LINCOLN, NE 68507 (NAICS 336350). OSHA activity number 340345842.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REXNORD INDUSTRIES, LLC
- Site address
- 6040 FLETCHER AVE
- City
- LINCOLN
- State
- NE
- ZIP
- 68507
- Mailing
- 6040 FLETCHER AVE, LINCOLN, NE 68507
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336350
- Employees
- 23
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 23, 2015
- Abate by
- May 13, 2015
- Penalty
- Initial $5,500 · Current $2,750 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire, deflagration and explosion hazards. The most recent example of this was found on the job site located at 6040 Fletcher Ave, Lincoln, NE 68507 where the employer has employees working on the rolling grinding stations using un-bonded 2.5 PVC pipe as part of the ventilation system, creating the potential for static charge to build up as product passes through the PVC and increase the possibility of sparking the dust and creating a deflagration ultimately leading to a secondary combustible dust explosion. Among other methods, feasible and acceptable methods of abatement are: Replace the electrically non-conductive PVC pipe with an electrically conductive duct work.
Recent events (2)
- — I (S) $2750
- — Z (S) $5500
More inspections at Rexnord Industries, LLC