Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEA REFRIGERATION NORTH AMERICA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GEA REFRIGERATION NORTH AMERICA, INC. in 3475 BOARD ROAD, YORK, PA 17406 (NAICS 333415). OSHA activity number 340364470.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GEA Refrigeration North America, INC. — free Get an email when a new federal OSHA severe-injury report for GEA Refrigeration North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3475 BOARD ROAD
City
YORK
State
PA
ZIP
17406
Mailing
3475 BOARD ROAD, YORK, PA 17406
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
260
Ownership type
A

4 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 5 2 instances 8 exposed
Issued
Apr 8, 2015
Abate by
May 4, 2015
Penalty
Initial $4,250 · Current $3,188 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a) Table Lift - Employees working around the table lift were exposed to arc rays from an insufficient amount of welding curtains setup to protect employees not welding, on or about February 11th, 2015.    b) Area Adjacent To Table Lift - Employees working the area adjacent to the table lift were exposed to arc rays from an insufficient amount of welding curtains setup to protect employees not welding, on or about February 11th, 2015.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3187.5
  • — Z (S) $4250

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 8, 2015
Abate by
May 4, 2015
Penalty
Initial $2,550 · Current $1,313 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:    a) Bertch Plate Roller - The energy control procedure for the Bertch Plate Roller did not cover multiple forms of energy exposing employees to possible stored hydraulic energy, on or about February 11th, 2015.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1312.5
  • — Z (S) $2550

1910.157 G02

Other-than-serious 1 instance 22 exposed
Issued
Apr 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter:  a) Office - The employer did not train employees required to extinguish incipient stage fires, on principles of fire extinguisher use and the hazards involved with incipient stage firefighting at least annually, on or about February 11th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06

Other-than-serious 1 instance 2 exposed
Issued
Apr 8, 2015
Abate by
May 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  a) Bertch Plate Roller- Employees were exposed to hazardous materials from a half full unmarked applicator bottle, on or about February 11th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.