Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STONE MASTERS AND GRANITE, INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STONE MASTERS AND GRANITE, INC in 1201 BERRYVILLE/13683 MADERO DR., EL PASO, TX 79928 (NAICS 238340). OSHA activity number 340367283.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stone Masters and Granite, INC — free Get an email when a new federal OSHA severe-injury report for Stone Masters and Granite, INC is published. One employer, no account, unsubscribe in one click.
Site address
1201 BERRYVILLE/13683 MADERO DR.
City
EL PASO
State
TX
ZIP
79928
Mailing
13683 MADERO DR., EL PASO, TX 79928
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238340
Employees
8
Ownership type
A

10 citations on file for this inspection.

1910.134 C01

Serious Gravity 10 6 instances 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use.  On or about February 11, 2015, and at times prior thereto, employees were overexposed to crystalline silica during the grinding of granite, and not protected by employer through establishing and implementing a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i)-(ix) with worksite specific procedures required for respirator use.  This condition exposed employees to health hazards.
Recent events (1)
  • — Z (S) $2800

1910.243 C01

Serious Gravity 10 6 instances 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a)   On or about February 11, 2015, and at times prior thereto, employees were using Makita 9565CV 5 inch electrical portable grinders to cut, grind and polish granite without guarding abrasive wheel.  This condition expose employees to struck-by hazards.
Recent events (1)
  • — Z (S) $2800

1910.303 B01 I

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.303(b)(1)(i): Suitability for installation and use in conformity with the provisions of this subpart; Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose.  On or about February 11, 2015, and at times prior thereto, employees were using a 125 volt wall receptacle as part of a shop-made electrical cord in the grinding area that was not suitable for that installation and use.  This condition exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (S) $2800

1910.304 G05

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.  On or about February 11, 2015, and at times prior thereto, employees were using a 125 volt wall receptacle as part of a shop-made electrical cord in the grinding area that was powered by a flexible electrical cord where the path to ground was not continuous and effective.  This condition exposed employees to electric shock hazards.
Recent events (1)
  • — Z (S) $2000

1910.305 B01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions.  On or about February 11, 2015, and at times prior thereto, employees working in the grinding area were using a 125 volt a shop-made flexible electrical cord that was not protected from abrasion.  This condition exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.   On or about February 11, 2015, and at times prior thereto, employees working in the grinding area (previous location) were using a 125 volt wall receptacle that was not provided with a cover. This condition expose employees to electrical shocks hazards.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  On or about February 11, 2015, and at times prior thereto, employees working in the grinding area (previous location) were using a 125 volt shop-made flexible extension cord that was not provided with a strain relief device that will prevent the transmission of cord tension to terminal screws.  This condition exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (S) $0

1910.1000 C

Serious Gravity 10 2 instances 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.1000(c): An employee(s) was exposed to Crystalline Silica as reparable quartz in excess of the 8-hour time weighted average limits of 10 mg/m3 e/ /% SiO2+2 listed in Table Z-3:  On or about April 02, 2015, and at times prior thereto, two employees grinding granite stone in the grinding area were exposed to respirable dust that exceeded the 8 hour time weighted average (TWA).  In the grinding area, where an employee performing grinding was exposed to respirable dust containing 25% crystalline quartz at an 8-hour time-weighted average (TWA). The permissible exposure limit (PEL) for respirable dust containing 25% crystalline quartz is 0.435 milligrams per cubic meter and the TWA was 0.840 mgr/m3.  The employee's exposure was 1.93 times the PEL. Sampling was conducted for 96 minutes on April 02, 2015. Zero exposure was assumed for the remaining minutes.  In the grinding area, where an employee performing grinding was exposed to respirable dust containing 25% crystalline quartz at an 8-hour time-weighted average (TWA). The permissible exposure limit (PEL) for respirable dust containing 25% crystalline quartz is 0.435 milligrams per cubic meter and the TWA was 0.536 mgr/m3.  The employee's exposure was 1.23 times the PEL. Sampling was conducted for 117 minutes on April 02, 2015. Zero exposure was assumed for the remaining minutes.
Recent events (1)
  • — Z (S) $2800

1910.1000 E

Serious Gravity 10 3 instances 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  February 11, 2015, and at times prior thereto, the employer did not provide administrative or engineering controls to minimize employee exposure to the different types of silica generated while performing granite stone grinding task in the workshop. This condition exposed employees to adverse health hazards associated with silica.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Other-than-serious 2 instances 6 exposed
Issued
Jul 28, 2015
Abate by
Aug 7, 2015
Penalty
Initial $400 · Current $400
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  On or about February 11, 2015, and at times prior thereto, the electrical control panel cabinet located by south east wall of the shop had unused openings that were not effectively closed.  This condition exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (O) $400

View Stone Masters and Granite, INC's full OSHA safety record →