LIVERPOOL, NY —
OSHA Inspection: WM RECYCLE AMERICA, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of WM RECYCLE AMERICA, LLC in 4550 STEELWAY BLVD. SOUTH, LIVERPOOL, NY 13090 (NAICS 236210). OSHA activity number 340373422.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WM RECYCLE AMERICA, LLC
- Site address
- 4550 STEELWAY BLVD. SOUTH
- City
- LIVERPOOL
- State
- NY
- ZIP
- 13090
- Mailing
- 4550 STEELWAY BLVD. SOUTH, LIVERPOOL, NY 13090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- Employees
- 28
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.37 A03
- Issued
- Feb 27, 2015
- Penalty
- Initial $2,890 · Current $2,168 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Warehouse, on or about 2/11/15: An emergency exit located near overhead door 8 was blocked with snow and could not be opened. b) Warehouse, on or about 2/11/15: An emergency exit was blocked with snow and could not be opened. c) Maintenance Part Storage Area, on or about 2/11/15: An emergency exit was blocked with snow and could not be opened.
Recent events (2)
- — I (S) $2167.5
- — Z (S) $2890
1910.101 B
- Issued
- Feb 27, 2015
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) in use were not properly supported to prevent them from being knocked over and Section 3.5.3 , Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinders containing flammable gases were stored within 20 feet of cylinders containing oxygen: a) Maintenance Part Storage Area, on or about 2/11/15: Compressed gas cylinders: Three acetylene cylinders were not secured to prevent them from being knocked over. b) Maintenance Part Storage Area, on or about 2/11/15: on or about 2/11/15: Compressed gas cylinders: Three (3) Acetylene Cylinders and Four (4) Oxygen Cylinders were stored with each other.
Recent events (2)
- — I (O) $0
- — Z (S) $2550
More inspections at WM Recycle America, LLC