Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WM RECYCLE AMERICA, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WM RECYCLE AMERICA, LLC in 4550 STEELWAY BLVD. SOUTH, LIVERPOOL, NY 13090 (NAICS 562920). OSHA activity number 340373463.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WM Recycle America, LLC — free Get an email when a new federal OSHA severe-injury report for WM Recycle America, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4550 STEELWAY BLVD. SOUTH
City
LIVERPOOL
State
NY
ZIP
13090
Mailing
4550 STEELWAY BLVD. SOUTH, LIVERPOOL, NY 13090
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562920
Employees
28
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2015
Abate by
Mar 24, 2015
Penalty
Initial $4,250 · Current $3,188 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the lifting device fails:    a)  Single Stream Sorting Area, on or about 2/11/15:  A 1 ton and a 1/4 ton Dayton overhead hoists was being used to lift the Shafting System from the Newspaper Sorting System to replace the rubber stars and with hoist have not been inspected on a frequent and periodic basis.    Among other methods one feasible and acceptable method to correct this hazard is to:    1. Conduct frequent and periodic inspections of the hoists for wear, deteriorations and malfunction as per ASME B30.16-2012, Section 16-2.
Recent events (2)
  • — I (S) $3187.5
  • — Z (S) $4250

1910.212 A01

Other-than-serious 1 instance 3 exposed
Issued
Feb 27, 2015
Penalty
Initial $3,400 · Current $0 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips:      a)  Weld Shop, on or about 2/11/15:  Dayton Band Saw was not protected with a guard on the unused portion of the blade on the left side.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3400

1910.304 G05

Other-than-serious 2 instances 2 exposed
Issued
Feb 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective:     a)  Single Stream Sorting Area, on or about 2/11/15:  Two Metal Stand Floor Fans had ground pins missing from plug ends.       b) Container Sorting Area, on or about 2/11/15:  Two Metal Stand Floor Fans had ground pins missing from plug ends.