OSHA Inspection: KING CARPENTRY

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of KING CARPENTRY in 1100 RHODE ISLAND, WASHINGTON, DC 20006 (NAICS 238130). OSHA activity number 340373778.

Watch King Carpentry — free Get an email when a new federal OSHA severe-injury report for King Carpentry is published. One employer, no account, unsubscribe in one click.
Establishment
KING CARPENTRY
Site address
1100 RHODE ISLAND
City
WASHINGTON
State
DC
ZIP
20006
Mailing
750 MILLER DRIVE SUITE B-3, LEESBURG, VA 20175
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights     a) On February 6, 2015 and at times thereto; Front of building; employees had erected a single pole scaffold which was not completely planked exposing them to a 30 foot fall to ground level.     Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 G01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system:  On February 6, 2015 and at times prior thereto; front area of building; employees working a scaffold system were not protected by both a guard rail system and a full body harness exposing them to an estimated 30 foot fall to ground level.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 A04

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds.  a) On February 6, 2015 and at times prior thereto; front of building; the scaffold system that the carpenters were using did not have diagonal bracing exposing employees to an estimated 30 foot fall to ground level.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 3 instances 6 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) On February 6, 2015 and at times prior thereto; throughout facility; employees framing a new residential Condo were observed walking on open platforms without fall protection in place to prevent them from falling 35 feet to ground level.       b) On February 6, 2015 and at times prior thereto; third floor front side; employees were walking through or working near wall openings without fall protection in place exposing them to 35 foot fall to ground level.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 10 2 instances 4 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    On February 6, 2015 and at times prior thereto; throughout the site; employee was using an 8 foot step ladder in the closed position while conducting framing or accessing the working platform on the scaffod.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

MACY'S