Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORBERT DENTRESSANGLE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NORBERT DENTRESSANGLE in 18249 QUARRY RD., WARRENTON, MO 63383 (NAICS 493120). OSHA activity number 340392471.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Norbert Dentressangle — free Get an email when a new federal OSHA severe-injury report for Norbert Dentressangle is published. One employer, no account, unsubscribe in one click.
Site address
18249 QUARRY RD.
City
WARRENTON
State
MO
ZIP
63383
Mailing
18249 QUARRY RD., WARRENTON, MO 63383
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
117
Ownership type
A

2 citations on file for this inspection.

1910.146 C04

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 25, 2015
Penalty
Initial $4,250 · Current $2,975 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146;  At the time of the inspection, it was determined that employees were entering confined spaces to repair springs on dock levelers. The employer had not implemented a confined space entry program.
Recent events (2)
  • — I (S) $2975
  • — Z (S) $4250

1910.147 C04 I

Other-than-serious 1 instance 4 exposed
Issued
Mar 25, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section;  At the time of the inspection, the employer had not developed and implemented machine specific procedures for the un-expected energization of equipment such as but not limited to condensers, compressors, and evaporators.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Norbert Dentressangle's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340392471.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.