Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JDF WELDING, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of JDF WELDING, INC. in 475 E. TUGALO STREET, TOCCOA, GA 30577 (NAICS 238120). OSHA activity number 340404136.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JDF Welding, INC. — free Get an email when a new federal OSHA severe-injury report for JDF Welding, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JDF WELDING, INC.
Site address
475 E. TUGALO STREET
City
TOCCOA
State
GA
ZIP
30577
Mailing
1150 RIDGEWAY ROAD, BOGART, GA 30622
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.756 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 8, 2015
Abate by
Aug 3, 2015
Penalty
Initial $5,600 · Current $4,000 Reduced
29 CFR 1926.756(a)(1): During the final placing of solid web structural members, the load was released from the hoisting line before the members were secured with at least two bolts per connection, of the same size and strength as shown in the erection drawings, drawn up wrench-tight or the equivalent as specified by the project structural engineer of record:  On or about February 10, 2015, during the installation of a structural member, an employee was exposed to a fall hazard of 14 feet to the lower level when the member was secured to a column using a loosened "C" clamp.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5600

1926.1402 B

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 8, 2015
Abate by
Jul 14, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.1402(b):  The equipment was assembled or used without ensuring that ground conditions were firm, drained, and graded to a sufficient extent so that, in conjunction (if necessary) with the use of supporting materials, the equipment manufacturer's specifications for adequate support and degree of the level of the equipment are met.  On or about February 10, 2015, five employees were exposed to a struck by hazard when the outriggers on the crane were resting on a surface that did not adequately support the equipment.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.1404 Q02

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 8, 2015
Abate by
Jul 20, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.1404(q)(2): The outriggers were not set to remove the equipment weight from the wheels:  On or about February 10, 2015, five employees working on the job site were exposed to a struck by hazard when the crane was not setup properly in that the wheels did not clear the ground.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.1417 D

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 8, 2015
Abate by
Jul 20, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.1417(d): The operator must not engage in any practice or activity that diverts his/her attention while actually engaged in operating the equipment, such as the use of cellular phones (other than when used for signal communications).   On or about February 10, 2015, with a load suspended and the steel erectors connecting the beam, the operator got on the back of the boom truck, turned away from the controls with his back towards the work to orient his drawings to the way the beams and columns were being erected.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.178 L01 I

Deleted Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2015
Abate by
Jul 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   On or about February 10, 2015, an employee driving a rough terrain forklift had not been trained or had his driving skills evaluated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JDF Welding, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340404136.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.