MONTOURSVILLE, PA —
OSHA Inspection: C & S CUSTOM CABINETS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of C & S CUSTOM CABINETS in 230 STREIBEIGH LANE UNIT 1, MONTOURSVILLE, PA 17754 (NAICS 337110). OSHA activity number 340406636.
Where did this inspection happen?
- Establishment
- C & S CUSTOM CABINETS
- Site address
- 230 STREIBEIGH LANE UNIT 1
- City
- MONTOURSVILLE
- State
- PA
- ZIP
- 17754
- Mailing
- 230 STREIBEIGH LANE UNIT 1, MONTOURSVILLE, PA 17754
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) At the facility: The employer did not establish a Lockout/Tagout Program consisting of energy control procedures, employee training and periodic inspections for those employees performing service and maintenance to machines including but not limited to the OptiSaw 2 and Thermwood CNC machines, on or about February 17, 2015. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.107 B05 IV
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2625.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) In the Production Area: The open face spray booth was not equipped with an approved automatic sprinkler. Employees were exposed to potential fire hazards on or about February 17, 2015. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
More inspections in this industry (NAICS 337110)
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
ORLANDO, FL—2026-07-15
ROSTOV, LLC
RICHMOND HILL, GA—2026-07-14
WILSON CABINETRY, LLC
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340406636.