RUPERT, ID —
OSHA Inspection: IDAHO EQUIPMENT & SHEET METAL COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of IDAHO EQUIPMENT & SHEET METAL COMPANY in 264 SOUTH HWY 24, RUPERT, ID 83350 (NAICS 332312). OSHA activity number 340413731.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IDAHO EQUIPMENT & SHEET METAL COMPANY
- Site address
- 264 SOUTH HWY 24
- City
- RUPERT
- State
- ID
- ZIP
- 83350
- Mailing
- 264 SOUTH HWY 24, RUPERT, ID 83350
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 33
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jul 8, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $2,380 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) Main bay: On or about 18 February, 2015, and at times prior thereto; the employer did not conduct periodic inspections of the energy control procedures for equipment in the main bay fabrication shop or the machine shop. Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2380
1910.147 D06
- Issued
- Jul 8, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6): Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished. a) Main Bay Fabrication Shop: On or about 18 February, 2015, and at times prior thereto, maintenance was performed on the Bandsaw, Model SH-500M without following adequate deenergization procedures to reduce the likelihood of electric shock after saw activation while changing out blades. Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Jul 8, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $2,380 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). a) On or about February 18, 2015 a Delta table saw, SN 97 1-1 96211 used for cutting high molecular weight plastic was missing an overhead guard. Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2380
1910.215 A04
- Issued
- Jul 8, 2015
- Abate by
- Jul 20, 2015
- Penalty
- Initial $1,785 · Current $1,068 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not used to support the work. Work rests were not adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest. a) Machine Room: On or about February 18, 2015 and times prior thereto, a Dunlap abrasive wheel grinder was missing a work rest. Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1068
- — Z (S) $1785
1910.215 B09
- Issued
- Jul 8, 2015
- Abate by
- Jul 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top did exceed one-fourth inch. a) Machine Room: On or about February 18, 2015 and times prior thereto a Dunlap abrasive wheel grinder adjustable tongue guard was measured at one inch from the wheel. Abatement documentation IS required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Jul 8, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $595 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. a) On or about February 18, 2015 employees operated Powered Industrial Trucks (PITs); Hyster 60 Fortis, H60FT, Serial L177B22030F, Toyota Forklift Truck, Model 8FG025, Serial 11652, Caterpillar 5E11, and have not received an evaluation of their performance every three years. Abatement certification and documentation IS required.
Recent events (2)
- — I (O) $0
- — Z (O) $595
1910.242 B
- Issued
- Jul 8, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $595 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. a) Main bay and Machine Shop: On or about and at times prior to, air hoses were used in the cleaning of machine parts without the a safety device in place and air pressure was measured between 70-100 psi: 1) Main bay and Machine Shop: HAAS VOP-C SL-30T, SN 3075145 - compressed air hose used for cleaning HAAS components was measured at 70 psi. 2) Main bay and Machine Shop: FADAL CNC MODEL 907-1, SN 012001022056 - compressed air hose used for cleaning FADAL components was measured above 100 psi. 3) Main bay and Machine Shop: ANDRYCHOW, TOOLMEX, MODEL TUG40, SN 8450 - compressed air hose used for cleaning components was measured at 70 psi. 4) Main bay and Machine Shop: SUMMIT machine - compressed air hose used for cleaning components was measured at 100 psi. 5) Main bay and Machine Shop: HAAS MILL TM-1, SN 32554 - compressed air hose used for cleaning components was measured at 70 psi. Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $595