Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C&D CONCRETE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C&D CONCRETE, INC. in 14910 W. EVANS PLACE, LAKEWOOD, CO 80228 (NAICS 238110). OSHA activity number 340413756.

Watch C&D Concrete, INC. — free Get an email when a new federal OSHA severe-injury report for C&D Concrete, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
C&D CONCRETE, INC.
Site address
14910 W. EVANS PLACE
City
LAKEWOOD
State
CO
ZIP
80228
Mailing
4150 OSCEOLA ST, DENVER, CO 80212
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1500.00 Reduced
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:    (a) On or about February 19, 2015, and at times prior, C&D Concrete, Inc. did not ensure that inspections of excavations, the adjacent areas, and protective systems were made by a competent person. Employees of C&D Concrete, Inc. were exposed to cave-in hazards while preparing to pour concrete for a retaining wall in an excavation approximately 11 feet deep, and 6 feet wide.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  (a) On or about February 19, 2015, C&D Concrete, Inc. did not ensure that its employees were protected from cave-in hazards while working in an excavation without adequate protective systems. Employees of C&D Concrete, Inc. were exposed to cave-in hazards while preparing to pour concrete in an excavation 6 feet wide, and 11 feet deep.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View C&D CONCRETE, INC.'s full OSHA safety record →