THOMSON, GA ·
OSHA Inspection: SCORE TECHNOLOGY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SCORE TECHNOLOGY, INC. in 2238 WASHINGTON ROAD, THOMSON, GA 30824 (NAICS 325222). OSHA activity number 340414093.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCORE TECHNOLOGY, INC.
- Site address
- 2238 WASHINGTON ROAD
- City
- THOMSON
- State
- GA
- ZIP
- 30824
- Mailing
- P.O. BOX 1810, THOMSON, GA 30824
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325222
- Employees
- 11
- Ownership type
- Private (A)
Citations
12 citations on file for this inspection.
1910.37 A04
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $2,400 · Current $1,320 Reduced
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: On or about February 19, 2015: Employees working at the facility located at 2238 Washington Road, Thomson, Georgia are exposed to entrapment hazards. The emergency exit lights over the exit doors in the facility were not operating properly to provide the employees lighted access to exit the building safely. 1. Emergency exit lights over the exit door in the spin finish storage area. 2. Emergency exit light over the side exit door was broken.
Recent events (2)
- · I (S) $1320
- · Z (S) $2400
1910.37 B06
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $1,600 · Current $880 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: On or about February 19, 2015: Employees working in the facility located at 2238 Washington Road, Thomson, Georgia are subjected to entrapment hazards. The employer did not ensure that the emergency exit sign over the exit door near the spin finish storage area was illuminated.
Recent events (2)
- · I (S) $880
- · Z (S) $1600
1910.147 C04 I
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 19, 2015: Employees working on and servicing equipment in the production area of the facility located at 2238 Washington Road, Thomson, Georgia are exposed to amputation injuries due to the employer not developing, documenting and utilizing hazardous energy control procedures for, but not limited to the Extruder and WTU 450 Winder (electrical and pneumatic).
Recent events (2)
- · I (S) $1100
- · Z (S) $2000
1910.157 E03
- Issued
- Aug 11, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $2,400 · Current $1,320 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check. On or about February 19, 2015: Employees working in the facility located at 2238 Washington Road in Thomson, Georgia were exposed to smoke inhalation and fire hazard in that the fire extinguishers had not been serviced for over four years.
Recent events (2)
- · I (S) $1320
- · Z (S) $2400
1910.178 G11
- Issued
- Aug 11, 2015
- Abate by
- Aug 17, 2015
- Penalty
- Initial $1,200 · Current $660 Reduced
General-duty citation text
29 CFR 1910.178(g)(11): Precautions were not taken to prevent open flames, sparks, or electric arcs in battery charging area(s): On or about February 19, 2015: Employees using the Hobart Accu-Charge Battery Charger to charge the Caterpillar Powered Industrial Truck in the storage area of the facility were exposed to an electrical arc from the exposed electrical wiring of the battery charger cable. The employer failed to remove the battery charger from service until the repairs could be made.
Recent events (2)
- · I (S) $660
- · Z (S) $1200
1910.305 G01 IV A
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $1,600 · Current $880 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about February 19, 2015: Employees working in the production room are exposed to electrical hazards where the employer used flexible cords for two small pumps used with the WTU 450 Winder in lieu of fixed wiring.
Recent events (2)
- · I (S) $880
- · Z (S) $1600
1910.1200 E01
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $1,200 · Current $660 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about February 19, 2015: Employees working in the production area of the facility are exposed to mild skin and respiratory irritation from working with products such as, but not limited to Ultramid BS 700 (polyamide), Polypropylene (white and conductive black), and Textile Spin Finish. The employer had not established a written hazard communication program.
Recent events (2)
- · I (S) $660
- · Z (S) $1200
1910.1200 E01 I
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. On or about February 19, 2015: Employees working in the production area of the facility are exposed to mild skin and respiratory irritation from working with products such as, but not limited to Ultramid BS 700 (polyamide), Polypropylene (white and conductive black), and Textile Spin Finish. The employer did not have an inventoried list of chemicals used in the worksite.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 G08
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s) On or about February 19, 2015: Employees working in the production area of the facility are exposed to mild skin and respiratory irritation from working with products such as, but not limited to Ultramid BS 700 (polyamide), Polypropylene (white and conductive black), and Textile Spin Finish. The employer did not make the safety data sheets readily available for the employees.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about February 19, 2015: Employees working in the production area of the facility are exposed to mild skin and respiratory irritation from working with products such as, but not limited to Ultramid BS 700 (polyamide), Polypropylene (white and conductive black), and Textile Spin Finish. The employer did not provide new GHS hazard communication training.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C02 I
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about February 19, 2015: The employer did not provide information in Appendix D of the respiratory protection standard to employees wearing the N95 respirator voluntarily.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 G02 III
- Issued
- Aug 11, 2015
- Abate by
- Sep 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about February 19, 2015: Employees working in the production room and servicing the winder are exposed to electrical shock hazards. The employer did not ensure that the electrical cord on the electrical box behind the Comoli WTU 450 Winder had strain relief to prevent damage.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 325222)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340414093.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.