BEAVER DAM, WI ·
OSHA Inspection: DAYTON LAMINA CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAYTON LAMINA CORPORATION in 151 INDUSTRIAL DRIVE SUITE A, BEAVER DAM, WI 53916 (NAICS 333513). OSHA activity number 340419167.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAYTON LAMINA CORPORATION
- Site address
- 151 INDUSTRIAL DRIVE SUITE A
- City
- BEAVER DAM
- State
- WI
- ZIP
- 53916
- Mailing
- 151 INDUSTRIAL DRIVE SUITE A, BEAVER DAM, WI 53916
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333513
- Employees
- 35
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 9, 2015
- Abate by
- Mar 23, 2015
- Penalty
- Initial $5,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: On or about February 24, 2015, lockout procedures were not utilized during set-up activities involving CNC coilers.
Recent events (3)
- · F (S) $0
- · C (S) $5100
- · Z (S) $5100
1910.147 D04 I
- Issued
- Mar 9, 2015
- Abate by
- Mar 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about February 24, 2015, lockout or tagout devices were not affixed to energy isolating device(s) on CNC coilers during set-up activities.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.212 A02
- Issued
- Mar 9, 2015
- Penalty
- Initial $3,400 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guards were not affixed to the machine where possible or secured elsewhere if for any reason attachment to the machine was not possible: On or about February 24, 2015, machine guards on CNC and mechanical coilers were not affixed or secured. The list of coilers includes, but is not limited to: a) Horsburgh & Scott CNC Coiler #2742 (Serial No. T-0809) b) BHS-Torin CNC Coiler #2606 (Serial No. 9593) c) Torrington Mechanical Coiler # 4966 (Serial No. 133269WL)
Recent events (3)
- · F (O) $1700
- · C (S) $3400
- · Z (S) $3400
1910.132 D02
- Issued
- Mar 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer had not verified that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identified the document as a certification of hazard assessment: On or about February 24, 2015, the employer had not certified the completion of a written workplace hazard assessment for personal protective equipment (PPE).
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 333513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340419167.