Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.D. SCREW MACHINE PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R.D. SCREW MACHINE PRODUCTS, INC. in 1054 GRUBB RD., SAN ANTONIO, TX 78219 (NAICS 332721). OSHA activity number 340419589.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.D. Screw Machine Products, INC. — free Get an email when a new federal OSHA severe-injury report for R.D. Screw Machine Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1054 GRUBB RD.
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
1054 GRUBB RD., SAN ANTONIO, TX 78219
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332721
Employees
16
Ownership type
A

7 citations on file for this inspection.

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 23, 2015
Abate by
May 3, 2015
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.215(a)(4):  Grinding machinery was not used with work rest(s) to support offhand grinding work:  Work space next to the Milltronics 7200 CNC Machine:  On or about February 05, 2015, employees were exposed to the hazard of being struck by flying projectiles, while operating a Baldor Grinder-Buffer, Cat. No. 612R, where the tool rest was not installed on the grinder.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 23, 2015
Abate by
May 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Work space next to the Milltronics 7200 CNC Machine:  On or about February 05, 2015, employees were exposed to the hazard of being struck by flying projectiles, while operating a Baldor Grinder-Buffer, Cat. No. 612R, where the distance between the wheel and the adjustable tongue exceeded 1/4".
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 23, 2015
Abate by
Apr 29, 2015
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)  Near the Boss 352 CNC Lathe:  On or about February 05, 2015, employees were exposed to the hazards of being struck by flying projectiles, while operating a compressed air blow gun to clean parts, where the tip pressure was not reduced to below 30 p.s.i.  b)  Near the Index B-60 Machine:  On or about February 05, 2015, employees were exposed to the hazards of being struck by flying projectiles, while operating a compressed air blow gun to clean parts, where the tip pressure was not reduced to below 30 p.s.i.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 23, 2015
Abate by
May 3, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  a)  West wall, between office and shop:  On or about February 05, 2015, employees were exposed to an electrical hazard, while plugging electrical tools and equipment into outlets near the GE Load Center, Cat No. TL 18DC3, circuit breaker panel "C", where this panel had a missing 1" knockout on the left side.  b)  West wall, between office and shop:  On or about February 05, 2015, employees were exposed to an electrical hazard, while working near the GE Load Center, Cat No. TL 18DC3, circuit breaker panel "C", where this panel had missing circuit breaker blanks at location 10 and 12.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 G01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 23, 2015
Abate by
Apr 29, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables were used as a substitute for the fixed wiring of a structure:  Near the Boss 342 CNC Lathe:  On or about February 05, 2015, employees were exposed to an electrical hazard, while plugging in electrical tools and equipment into a quad receptacle, which was permanently mounted to the building structure, where the receptacle's electricity was being supplied by a flexible cord.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.334 A02 I

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 23, 2015
Abate by
Apr 29, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)  West wall, between office and shop:  On or about February 05, 2015, employees were exposed to an electrical hazard, while plugging in a 2 bulb, 4 foot, fluorescent light fixture, where the extension cord being used to power the light fixture was missing a grounding pin.  b)  Next the Boss 342 CNC Lathe:  On or about February 05, 2015, employees were exposed to an electrical hazard, while plugging in a 2 bulb, 8 foot, fluorescent light fixture, where the extension cord being used to power the light fixture was frayed at the plug end, which exposed the extension cord's internal wiring and lacked proper strain relief.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1904.32 A04

Other-than-serious 1 instance 16 exposed
Issued
Apr 23, 2015
Penalty
Initial $1,000 · Current $600 Reduced
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30.  1054 Grubb Rd., San Antonio, TX 78219:  On or about February 05, 2015, the employer failed to post the annual summary of work-related injuries and illnesses for year 2014.