OSHA Inspection: MID-STATE INDUSTRIES OPERATING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MID-STATE INDUSTRIES OPERATING, INC. in 908 BOB KING DRIVE, ARCOLA, IL 61910 (NAICS 331221). OSHA activity number 340423557.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mid-State Industries Operating, INC. — free Get an email when a new federal OSHA severe-injury report for Mid-State Industries Operating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
908 BOB KING DRIVE
City
ARCOLA
State
IL
ZIP
61910
Mailing
908 BOB KING DRIVE, ARCOLA, IL 61910
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
8
Ownership type
A

6 citations on file for this inspection.

1910.133 A01

Other-than-serious 1 instance 1 exposed
Issued
May 8, 2015
Abate by
May 14, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:        Mid-State Industries Operating, Inc. had an employee exposed to struck-by hazards in the eyes without eye protection, while cutting metal banding during the loading and unloading of steel on the Slitter Line.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

1910.147 C04 I

Serious Gravity 5 3 instances 2 exposed
Issued
May 8, 2015
Abate by
May 20, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:        Mid-State Industries Operating, Inc. had employees perform maintenance and setup operations on equipment including but not limited to: Slitter, Cut to Length, and Whirlwind Saw, and the employer did not develop, document, and utilize an energy control procedure for each piece of equipment.  These energy control procedures would include the following:      a. A specific statement of the intended use of the procedure,   b. Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy,    c. Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them, and   d. Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 8, 2015
Abate by
May 14, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   Mid-State Industries Operating, Inc. had employees perform maintenance and setup operations on equipment including but not limited to: Slitter Line, Cut to Length, and Whirlwind Saw, and the employer did not conduct an energy control inspection to ensure that all hazardous energy was controlled during maintenance and setup operations and the requirements of 1910.147 were met.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
May 8, 2015
Abate by
May 14, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:         Mid-State Industries Operating, Inc. had employees exposed to amputation hazards while performing setup operations on the Slitter line approximately 16-20 times a week, and the employer did not lockout all hazardous energy sources.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
May 8, 2015
Abate by
May 14, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Mid-State Industries Operating, Inc. had employees exposed to unguarded rotating and moving parts, during the operation of the Cut to Length machine.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
May 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):       Mid-State Industries Operating, Inc. had employees exposed to amputation hazards, while operating the unguarded Whirlwind Saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340423557.