Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE NABER GROUP INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE NABER GROUP INC. in 77 S. STOPL, AURORA, IL 60502 (NAICS 238910). OSHA activity number 340424795.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Naber Group INC. — free Get an email when a new federal OSHA severe-injury report for The Naber Group INC. is published. One employer, no account, unsubscribe in one click.
Site address
77 S. STOPL
City
AURORA
State
IL
ZIP
60502
Mailing
32919 MAPLE GROVE DR, BURLINGTON, WI 53105
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
10
Ownership type
A

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2015
Abate by
Aug 5, 2015
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1):  The employer failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:    The Naber Group Inc. failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:    Citation Number                     Item Number                           Abatement Date  01                                           1                                             05/04/2015  01                                           2a,2b,3                                   04/20/2015   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $400

1903.19 D01

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2015
Abate by
Aug 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.    The Naber Group Inc. failed to submit documents to OSHA verifying that each of the following cited violations had been corrected:     Citation Number                     Item Number                           Abatement Date  01                                           4                                            04/20/2015
Recent events (1)
  • — Z (O) $0

1926.21 B02

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 8, 2015
Abate by
May 4, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:   On or about February 25, 2015 employees were not provided with training to recognize or minimize the hazards associated with demolition and construction work.   Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $2000

1926.405 A02 II A

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 8, 2015
Abate by
Apr 20, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.405(a)(2)(ii)(A): Temporary wiring feeder conductors were not run as multiconductor cord or cable assemblies or within raceways; or, where not subject to physical damage, run as open conductors on insulators not more than 10 feet apart:  On or about February 25, 2015 employees were exposed to electrical shock where a temporary lighting circuit was exposed to physical damage.  Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $1600

1926.405 A02 II F

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 8, 2015
Abate by
Apr 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension:   On or about February 25, 2015 temporary lights were suspended by the electrical cable, exposing employees to an electrical shock.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $0

1926.416 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 8, 2015
Abate by
Apr 20, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:   On or about February 25, 2105 employees were permitted to work in an area where a 220 volt circuit was not effectively guarded, exposing employees to electrocution.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $2000

1926.501 B04 I

Serious Gravity 10 3 instances 7 exposed
Issued
Apr 8, 2015
Abate by
Apr 20, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the hole:   On February 25, 2015 employees were not protected from falling through exposed floor holes, exposing employees to a 10 foot fall on the following floors.   Instance a)  Employees were exposed on the second floor west side.   Instance b)  Employees were exposed on the third floor west side.   Instance c)  Employees were exposed on the fourth floor west side.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2800

View The Naber Group INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340424795.