Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KENSAL FARMERS ELEVATOR COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KENSAL FARMERS ELEVATOR COMPANY in 611 PARKER STREET, KENSAL, ND 58455 (NAICS 424510). OSHA activity number 340426006.

Watch Kensal Farmers Elevator Company — free Get an email when a new federal OSHA severe-injury report for Kensal Farmers Elevator Company is published. One employer, no account, unsubscribe in one click.
Site address
611 PARKER STREET
City
KENSAL
State
ND
ZIP
58455
Mailing
P.O. BOX 68, KENSAL, ND 58455
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
10
Ownership type
A

4 citations on file for this inspection.

1910.272 J02 II

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.272(j)(2)(ii): The employer did not immediately remove any fugitive grain dust accumulations whenever they exceeded 1/8-inch (.32 cm) at priority housekeeping areas, pursuant to the housekeeping program for grain elevators:     (a) On or about January 28, 2015, and at times prior to that date, for employees exposed to fire and/or explosion hazards while performing work activities in the main elevator where dust accumulations on the floor in the boot pit were in excess of 1/8-inch in depth at Kensal Farmers Elevator Company, located at 611 Parker Street in Kensal, North Dakota.     (b) On or about January 28, 2015, and at times prior to that date, for employees exposed to fire and/or explosion hazards while performing work activities in the main elevator where dust accumulations on the floor area of the bin floor level with piles up to approximately 8 inches in depth at Kensal Farmers Elevator Company, located at 611 Parker Street in Kensal, North Dakota.     (c) On or about January 28, 2015, and at times prior to that date, for employees exposed to fire and/or explosion hazards while performing work activities in the main elevator where dust accumulations on the floor in the head house were up to 3/4-inch in depth at Kensal Farmers Elevator Company, located at 611 Parker Street in Kensal, North Dakota.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.272 Q05

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.272(q)(5): The employer did not equip bucket elevators with a motion detection device which will shut down the bucket elevator when the belt speed is reduced by no more than 20% of the normal operating speed:     (a) On or about January 28, 2015, and at times prior to that date, for employees exposed to fire and/or explosion hazards while performing work activities in the main elevator house where the facility has a holding capacity of approximately 3.7 million bushels at Kensal Farmers Elevator Company, located at 611 Parker Street in Kensal, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 Q06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.272(q)(6)(i): The employer did not equip bucket elevators with a belt alignment monitoring device which will initiate an alarm to employees when the belt is not tracking properly:     (a) On or about January 28, 2015, and at times prior to that date, for employees exposed to fire and/or explosion hazards while performing work activities in the main elevator house where the facility has a holding capacity of approximately 3.7 million bushels at Kensal Farmers Elevator Company, located at 611 Parker Street in Kensal, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 E02

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.272(e)(2): Employees assigned special tasks in the grain handling facility, such as bin entry and handling of flammable or toxic substances, were not provided training to perform these tasks safely:   (a)  On or about January 26, 2015, and at times prior to that date, for the employees performing atmospheric testing with a Gas Alert Quattro 4-gas detector prior to bin entry operations where the employees lacked the knowledge to properly evaluate safe entry conditions at Kensal Farmers Elevator Company, located at 611 Parker Street in Kensal, North Dakota.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340426006.