Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIOARRA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIOARRA, INC. in 171 RUTH ROAD SUITE B, HARLEYSVILLE, PA 19438 (NAICS 325411). OSHA activity number 340426352.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bioarra, INC. — free Get an email when a new federal OSHA severe-injury report for Bioarra, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BIOARRA, INC.
Site address
171 RUTH ROAD SUITE B
City
HARLEYSVILLE
State
PA
ZIP
19438
Mailing
171 RUTH ROAD SUITE B, HARLEYSVILLE, PA 19438
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325411
Employees
60
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 4, 2015
Penalty
Initial $2,023 · Current $1,517 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards while using improperly maintained mobile ladder stands.   a) Shop - on or about February 11, 2015, a nine riser mobile ladder stand being used by production employees was not properly fitted with the rubber safety stops required to prevent movement when the ladder was in use.  ABATEMENT NOTE:  Among other methods, one feasible and acceptable abatement method to correct this hazard is: Comply with the manufacturer's requirements and ANSI A14.7-1991 for Mobile Ladder Stands and discontinue use until repairs are completed. Units that are damaged or weakened from any cause shall not be used until repairs are completed.  Units that are damaged subsequent to their receipt, and/or are worn beyond repair shall be destroyed.  Never climb a damaged ladder stand or ladder.
Recent events (2)
  • — I (S) $1517.25
  • — Z (S) $2023

1910.23 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 4, 2015
Abate by
Jun 16, 2015
Penalty
Initial $2,380 · Current $1,785 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.  a) Shop - on or about February 11, 2015, employees working from an elevated working surface, being used to store supplies approximately nine feet, six inches above a lower level, were not guarded with standard railings or any other means of fall protection.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2380

1910.37 A03

Serious Gravity 5 1 instance 15 exposed
Issued
Jun 4, 2015
Penalty
Initial $2,023 · Current $1,517 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) Main exit from the shop area - On or about February 11, 2015, the emergency exit that serves the shop area was obstructed by boxes, equipment and supplies potentially delaying employee egress in the event of an emergency.
Recent events (2)
  • — I (S) $1517.25
  • — Z (S) $2023

1910.305 G01 IV A

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 4, 2015
Abate by
Jun 30, 2015
Penalty
Initial $2,380 · Current $1,785 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure.  a) Shop - on or about February 11, 2015, flexible cords were in use to provide power to various scales, lights, refrigerators and machines as a substitute to fixed wiring.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2380

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340426352.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.