Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C PRICE ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C PRICE ENTERPRISES, INC. in 1898 E 56TH ROAD, LECOMPTON, KS 66050 (NAICS 561730). OSHA activity number 340427939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C Price Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for C Price Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1898 E 56TH ROAD
City
LECOMPTON
State
KS
ZIP
66050
Mailing
1898 E 56TH ROAD, LECOMPTON, KS 66050
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
20
Ownership type
A

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Employees accessing the overhead storage area in the shop were exposed to injury from an 8 foot fall hazard.  Standard guard rails were not provided for the overhead storage area.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.101 B

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  Employees working in the shop storage area were exposed to a struck by hazard.  One compressed gas cylinder of N.O.S. was in storage and was not secured to prevent it from being knocked over, possibly causing damage to the valve assembly.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  In the shop area, the Ryobi 6 inch bench grinder was missing the tongue guard resulting in an approximate 1 inch gap between the abrasive wheel and the grinder housing, exposing employees to a struck by hazard.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Employees working in the shop area were exposed to an electrical shock hazard.  The energized 220 VAC outlet box on the drop cord providing power to the Miller welder was missing a knockout.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.305 B02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On the east wall of the shop supply room, a two gang electrical box housing 110 VAC light switches and a single gang electrical  box housing a 110 VAC receptacle were not provided with faceplates, exposing employees to an electrical shock from the energized conductors.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.   The overhead storage area above the break room and the ground level storage area had not been marked indicating the load capacity of the floor.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View C Price Enterprises, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340427939.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.