Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TITAN MODULAR SYSTEMS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TITAN MODULAR SYSTEMS, INC. in 162 INDUSTRIAL DRIVE, ALMA, GA 31510 (NAICS 321991). OSHA activity number 340428069.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Titan Modular Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Titan Modular Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
162 INDUSTRIAL DRIVE
City
ALMA
State
GA
ZIP
31510
Mailing
162 INDUSTRIAL DRIVE, ALMA, GA 31510
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321991
Employees
200
Ownership type
A

1 citation on file for this inspection.

1910.95 C01

Serious Gravity 1 1 instance 10 exposed
Issued
Jun 25, 2015
Abate by
Sep 1, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    (a)  In the Plant 1 Floor Decking Area, on or about February 26, 2015, a hearing conservation program was not implemented for the employee who was exposed to noise at 171% of the action level (8-hour time-weighted average sound level of 85 dBA) or an equivalent sound level of 88.8 dBA during the 352 minute sampling period, resulting in a noise hazard.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

View Titan Modular Systems, INC.'s full OSHA safety record →