OSHA Inspection: H.R. WEAVER BUILDING SYSTEMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of H.R. WEAVER BUILDING SYSTEMS in ROUTE 422 AND CLEAR SPRING ROAD, ANNVILLE, PA 17003 (NAICS 236220). OSHA activity number 340429042.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H.R. Weaver Building Systems — free Get an email when a new federal OSHA severe-injury report for H.R. Weaver Building Systems is published. One employer, no account, unsubscribe in one click.
Site address
ROUTE 422 AND CLEAR SPRING ROAD
City
ANNVILLE
State
PA
ZIP
17003
Mailing
47 PALMYRA-BELLGROVE ROAD, ANNVILLE, PA 17003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.451 C02 IV

Other-than-serious 2 instances 4 exposed
Issued
May 15, 2015
Abate by
Jun 11, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use:    a) West Side of Building - The employer used a Gradall 534C material handler to support a scaffold platform that was not designed by the manufacturer for that purpose, on or about February 26, 2015.      b) East Side of Building - The employer used a Gradall 534D-42 material handler to support a scaffold platform that was not designed by the manufacturer for that purpose, on or about February 26, 2015.    Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.451 F05

Serious Gravity 1 1 instance 2 exposed
Issued
May 15, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.451(f)(5): Scaffolds were moved horizontally while employees were on them although the scaffolds were not designed for such movement by a registered professional engineer:  a) West Side of Building - An employee was observed standing on an elevated work platform attached to the forks of a Gradall 534C while the operator moved the platform horizontally and was exposed to an approximate 8 foot fall hazard, on or about February 26, 2015.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1200

1926.602 D

Serious Gravity 1 1 instance 2 exposed
Issued
May 15, 2015
Abate by
Jun 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l):  a) West Side of Building - Employees were observed operating a Gradall 534C material handler and did not receive a combination of formal instruction, practical training, and evaluation of the operator's performance, on or about February 26, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 2 instances 4 exposed
Issued
May 15, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a) West Side of Building - Employees were observed working from an elevated work platform attached to the forks of a Gradall 534C and were not protected from an approximate 15 foot fall hazard to the ground below, on or about February 26, 2015.  b) East Side of Building - Employee were observed working from an elevated work platform attached to the forks of a Gradall 534D-42 and were not protected from an approximate 15 foot fall hazard to the ground below, on or about February 26, 2015.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.454 A

Serious Gravity 10 1 instance 4 exposed
Issued
May 15, 2015
Abate by
Jun 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  a) Job Site - Employees working from elevated work platforms attached to the tines of Gradall material handlers were not trained in the recognition and avoidance of hazards associated with elevated work platform usage and how to correct those hazards, such as but not limited to, fall hazards, on or about February 26, 2015.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.453 B02 V

Serious Gravity 5 2 instances 4 exposed
Issued
May 15, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:  a) West Side of Building - Employees used a JLG 400S aerial lift to access and egress an elevated work platform and did not don a body belt (or harness) with lanyard attached to the boom or basket and were exposed to fall hazards up to approximately 15 feet, on or about February 26, 2015.  b) East Side of Building - Employees used a Snorkelift A42 aerial lift to access and egress an elevated work platform and did not don a body belt (or harness) with lanyard attached to the boom or basket and were exposed to fall hazards up to approximately 15 feet, on or about February 26, 2015.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1926.602 C01 VI

Serious Gravity 10 1 instance 2 exposed
Issued
May 15, 2015
Abate by
Jun 11, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks; the load engaging means was not fully lowered when leaving a powered industrial truck unattended:    a) West Side of Building - Employees were observed working from an elevated work platform placed on the forks of a Gradall 534C material handler. The operator had dismounted the material handler leaving no one at the controls, employees were exposed to an approximate 15 foot fall hazard, on or about February 26, 2015.    Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

View H.R. Weaver Building Systems's full OSHA safety record →