MOOSIC, PA —
OSHA Inspection: ALBRIGHT PRECISION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALBRIGHT PRECISION, INC. in 4 ROCKY GLEN ROAD, MOOSIC, PA 18507 (NAICS 238220). OSHA activity number 340434463.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALBRIGHT PRECISION, INC.
- Site address
- 4 ROCKY GLEN ROAD
- City
- MOOSIC
- State
- PA
- ZIP
- 18507
- Mailing
- P.O. BOX 3479, SCRANTON, PA 18505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 34
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- May 29, 2015
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) In the CNC Turret Area: The side access door of the Amada PEGA-357 turret punch press was not guarded, exposing employees to caught-by hazards from rotating parts as observed on or about February 25, 2015. ABATED DURING INSPECTION. NO ABATEMENT CERTIFICATION REQUIRED.
Recent events (1)
- — Z (S) $3500
1910.147 C06 I
- Issued
- May 29, 2015
- Abate by
- Jun 10, 2015
- Penalty
- Initial $140 · Current $140
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the Facility: An annual inspection of the energy control procedures (Lockout/Tagout) was not conducted at least annually by the employer, on or about February 25, 2015 ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED FOR THIS VIOLATION. Albright Precision, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 314161159, citation number 2, item number 1 and was affirmed as a final order on 3/24/2011, with respect to a workplace located at 4 Rocky Glen Road, P.O. Box 3479, Scranton, PA 18505.
Recent events (1)
- — Z (R) $140
More inspections at Albright Precision, INC.