Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SLIDEMATIC PRECISION COMPONENTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SLIDEMATIC PRECISION COMPONENTS, INC. in 1303 SAMUELSON ROAD, ROCKFORD, IL 61109 (NAICS 332722). OSHA activity number 340437284.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Slidematic Precision Components, INC. — free Get an email when a new federal OSHA severe-injury report for Slidematic Precision Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1303 SAMUELSON ROAD
City
ROCKFORD
State
IL
ZIP
61109
Mailing
1303 SAMUELSON ROAD, ROCKFORD, IL 61109
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
130
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 39 exposed
Issued
Jul 15, 2015
Abate by
Oct 30, 2015
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    Production machines: employees were assigned to perform maintenance and servicing tasks when the hazardous energy control program (i.e. lockout tagout) was not established and implemented in the workplace. Training and periodic inspections were not conducted. Employees were exposed to hazards capable of causing hand(s) and finger(s) amputation from unexpected start-up.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3780
  • — Z (S) $6300

1910.147 F01

Serious Gravity 10 1 instance 35 exposed
Issued
Jul 15, 2015
Abate by
Apr 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(1): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment or component thereof, the sequence of actions were not followed:    Production, cold heading machines: employees were assigned to perform setup and changeover tasks that exposed them to hand(s) and finger(s) caught-in between hazards capable of causing amputation. Procedures for machines testing or positioning (setup) in the point-of-operation and associated danger zones were not established in a sequence of actions required to maintain the integrity and continuity of employee protection as follows:    (a) clear machines of tools and materials;   (b) remove employees from the hazardous areas around the machine;   (c) remove the lockout/tagout devices;   (d) energize the machine and employ effective employee protection while testing or positioning machinery;   (e) and, turn off all systems, isolate the machine from the energy source, and reapply lockout/tagout devices as specified, if additional servicing or maintenance is required.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 35 exposed
Issued
Jul 15, 2015
Abate by
Apr 22, 2016
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    Production, cold heading machines: on or about February 3, 2015, employees were assigned to perform setup and changeover tasks that exposed them to hand(s) and finger(s) caught-in between hazards capable of causing amputation when equipment was not de-energized and other safeguarding was not provided.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3780
  • — Z (S) $6300

View Slidematic Precision Components, INC.'s full OSHA safety record →