Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLLISION CARE AUTO BODY CENTERS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of COLLISION CARE AUTO BODY CENTERS, INC. in 21ST & WASHINGTON AVENUE, PHILADELPHIA, PA 19146 (NAICS 811121). OSHA activity number 340437466.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Collision Care Auto Body Centers, INC. — free Get an email when a new federal OSHA severe-injury report for Collision Care Auto Body Centers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
21ST & WASHINGTON AVENUE
City
PHILADELPHIA
State
PA
ZIP
19146
Mailing
21ST & WASHINGTON AVENUE, PHILADELPHIA, PA 19146
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
20
Ownership type
A

8 citations on file for this inspection.

1910.106 E02 III

Serious Gravity 5 1 instance 15 exposed
Issued
Aug 24, 2015
Abate by
Oct 9, 2015
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1910.106(e)(2)(iii): Areas in which flammable liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided:    a) Collision Care Auto Body Centers, Inc., South Philadelphia - The employer did not ensure that the mixing room, the area where the Paint Gun Washer and the Sidewinder solvent recovery unit are located were separated by adequate distance or construction having adequate fire resistance, exposing employees to fire hazards.  Observed on or about 2/25/15.     b) Collision Care Auto Body Centers, Inc., South Philadelphia - The employer did not ensure that drainage or other means to control spills was provided for the 5 and 55 gallon drums for the paint gun washer waste and the 5 gallon drum for the waste from the solvent recovery unit waste, exposing employees to potential fire hazards.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.106 E06 II

Serious Gravity 5 1 instance 15 exposed
Issued
Aug 24, 2015
Abate by
Sep 11, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees F (37.8 degrees C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected:      a) Collision Care Auto Body Centers, Inc., South Philadelphia,  Shop Area, Mixing Room - The employer did not ensure that containers of flammable liquids with a flashpoint below 100 degrees F, including but not limted to Premium Wash Thinner, DC 3000 Clear coat, DCH 3095 High Temperature Hardener, and other paints and solvents were bonded and grounded while liquids were being transferred, exposing employees to fire hazards Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.107 J02

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
Aug 24, 2015
Abate by
Oct 9, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.107(j)(2): Alternate use prohibited. Spray booths, rooms, or other enclosures used for spraying operations shall not alternately be used for the purpose of drying by any arrangement which will cause a material increase in the surface temperature of the spray booth, room, or enclosure:  a) Collision Care Auto Body Centers, Inc., South Philadelphia -   The employer did not provide separate locations for spray painting and drying autos and auto body parts.  Employees used the same spray booths for spraying and drying with air heated to 140 degrees, exposing employees to fire hazards.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.133 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 24, 2015
Abate by
Sep 11, 2015
Penalty
Initial $4,200 · Current $2,940 Reduced

Hazardous substances H130

29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a) Collision Care Auto Body Centers, Inc., South Philadelphia -  The employer did not ensure that employees wore chemical splash goggles when they spray painted auto body parts with paints containing hazardous chemicals including isocyanates and solvents, exposing employees to permanent eye damage.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4200

1910.134 F01

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Aug 24, 2015
Abate by
Oct 9, 2015
Penalty
Initial $2,100 · Current $0 Reduced

Hazardous substances H130

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  a) Collision Care Auto Body Centers, Inc., South Philadelphia - Employees were required to wear 3M half-mask disposable respirators with organic vapor cartridges and P95 pre-filters when they spray-painted auto body parts.  The employer did not fit-test employees to ensure a proper fitting respirator in accordance with this section.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.134 K01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2015
Abate by
Sep 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1)(i): The employer did not ensure that each user could demonstrate knowledge of why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator:  a) Collision Care Auto Body Centers, Inc., South Philadelphia - The employer did not ensure that employees knew how improper fit and usage could compromise the protective effective of the respirator.  Employees wore 3M half-mask disposable respirators when the spray painted auto body parts and were exposed to solvents and paints containing isocyanates.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 24, 2015
Abate by
Sep 11, 2015
Penalty
Initial $0 · Current $0

Hazardous substances H130

29 CFR 1910.134(k)(1)(iv): The employer did not ensure that each user could demonstrate knowledge of how to inspect, put on, remove, use, and check the seals of the respirator:  a) Collision Care Auto Body Centers, Inc., South Philadelphia - The employer did not ensure that employees knew how to check the respirator seals.  Employees wore 3M half-mask disposable respirators when the spray painted auto body parts and were exposed to solvents and paints containing isocyanates.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 24, 2015
Abate by
Sep 11, 2015
Penalty
Initial $4,200 · Current $2,940 Reduced

Hazardous substances H130

29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes.    a) Collision Care Auto Body Centers, Inc., South Philadelphia - The employer did not select and require employees to use appropriate hand protection such as, but not limited to butyl gloves, etc. to protect employees from chemical hazards such as isocyanates containing hardners when they sprayed auto body parts.  The employer provided employees with disposable latex gloves, exposing employees to hazards from skin absorption of chemicals such as, but not limited to isocyanates.  Observed on or about 2/25/15.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340437466.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.