LOCKPORT, NY —
OSHA Inspection: G M COMPONENTS HOLDINGS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of G M COMPONENTS HOLDINGS LLC in 200 UPPER MOUNTAIN ROAD, LOCKPORT, NY 14094 (NAICS 336399). OSHA activity number 340437722.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G M COMPONENTS HOLDINGS LLC
- Site address
- 200 UPPER MOUNTAIN ROAD
- City
- LOCKPORT
- State
- NY
- ZIP
- 14094
- Mailing
- 200 UPPER MOUNTAIN ROAD, LOCKPORT, NY 14094
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 1450
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E06 II
- Issued
- Mar 13, 2015
- Penalty
- Initial $3,613 · Current $3,613
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) On or about 03/05/15, in the Flux Mix room, employee transferred Isopropyl Alcohol (Category 2) from 55 gallon drum to a secondary container (plastic bucket) without using an electrical bonding wire between the containers. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $3613
- — C (S) $3613
- — Z (S) $3613
1910.212 A01
- Issued
- Mar 13, 2015
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: Rotating parts. a) On or about 03/05/15, in the Flux Room (Dept 491), the guard was missing on the rotating spindle on pump on top of flux mixer.
Recent events (3)
- — J (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.303 B02
- Issued
- Mar 13, 2015
- Penalty
- Initial $2,550 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 03/05/15, in Building 7, the electrical outlet BRK#7 located to the right of the water fountain was used to energize the water fountain and did not have a Ground-Fault Circuit-Interrupter as required by the National Electric Code (2014, section 422.52). b) On or about 03/05/15, in Building 7, the electrical outlet BRK#8 located to the right of the water fountain was used to energize the water fountain and did not have a Ground-Fault Circuit-Interrupter as required by the National Electric Code (2014, section 422.52). NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $2000
- — C (S) $2550
- — Z (S) $2550
1910.305 G01 IV A
- Issued
- Mar 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 03/05/15, in the wire room, an extension cord was used in place of fixed wiring to energize water fountain. b) On or about 03/05/15, in Building 8 Sec. BB77, an extension cord was used in place of fixed wiring to energize water fountain. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at G M Components Holdings LLC
View G M Components Holdings LLC's full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340437722.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.