Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WATTS ELECTRIC COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WATTS ELECTRIC COMPANY in 14TH ST. AND MILITARY RD., LINCOLN, NE 68505 (NAICS 238210). OSHA activity number 340439298.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Watts Electric Company — free Get an email when a new federal OSHA severe-injury report for Watts Electric Company is published. One employer, no account, unsubscribe in one click.
Site address
14TH ST. AND MILITARY RD.
City
LINCOLN
State
NE
ZIP
68505
Mailing
13351 DOVER STREET, WAVERLY, NE 68462
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 1 exposed
Issued
Jun 15, 2015
Abate by
Jul 31, 2015
Penalty
Initial $4,900 · Current $2,450 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.    The employer is failing to protect employees from potential struck by and caught between hazards associated with failing to use required tools and communications means as required in the manufacturers operators manual.  The most recent example of this was found on the job site located at 14th Street and Military Road, Lincoln, NE 68505 where the employer has employees disconnecting drill rods using tools and methods not authorized in accordance with the operators manual for the American Auger DD-110 Horizontal Drilling Machine.  Instances include but are not limited to:    i. Employees leveraging the Bukup Tongs against the ground and the drill machine operator using the power of the machine to assist in breaking the drill rods apart, a practice not accepted by the Horizontal Direction Drilling Good Practices Guidelines.      ii. Employees using the power of a CAT Model 430D Back Hoe and applying pressure directly to the Bukup Tongs as a method of applying leverage to break the drill rods apart.    iii. Employees attempting to communicate with hand signals from 570 feet away and obstructed view in lieu of the radio communications mandated in the operators manual for the DD-110 Horizontal Drilling Machine.      Among other methods, feasible and acceptable methods of abatement are:      1.     When disconnecting drill rods from each other, use either a hydraulic or manual remote breakout wrench which will ensure that employees are clear of the rods as they are slowly separated apart.         2.     When conducting horizontal boring operations the employer shall use radio communications as the means of communicating between the drill and exit site.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340439298.