OMAHA, NE —
OSHA Inspection: ASPEN EQUIPMENT CO.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ASPEN EQUIPMENT CO. in 11475 S 153RD STREET, OMAHA, NE 68138 (NAICS 423810). OSHA activity number 340441013.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASPEN EQUIPMENT CO.
- Site address
- 11475 S 153RD STREET
- City
- OMAHA
- State
- NE
- ZIP
- 68138
- Mailing
- 11475 S 153RD STREET, OMAHA, NE 68138
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423810
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 L01
- Issued
- Jun 26, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.178(l)(1): The employer did not ensure that each power industrial truck operator was competent to operate a power industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in paragraph (l): Jobsite: The employer failed to assure that each forklift operator was competent to operate the Crown RR 5000 (SN: 1A204151) and/or the Clark C35L (SN: P232L-0843-9839-CNF) powered industrial trucks, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.178 L06
- Issued
- Jun 26, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): Jobsite: The employer had not certified that each industrial truck operator has been trained and evaluated in the use of powered industrial trucks as required by paragraph (l) of 1910.178, such as, but not limited to, employees operating the Crown RR 5000 (SN: 1A204151) and/or the Clark C35L (SN: P232L-0843-9839-CNF) powered industrial trucks without current certification. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G01
- Issued
- Jun 26, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: Jobsite: Safety Data Sheets for Argon, Acetylene, Propane or Oxygen were not maintained at the jobsite. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.1200 H01
- Issued
- Jun 26, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Jobsite: Employees are required to perform tasks, such as, but not limited to, welding and torch cutting exposing them to hazardous chemicals. Yet the employer is failing to provide employees training to recognize, evaluate and control exposure to hazardous chemicals including, but not limited to, Manganese Fumes, Iron Oxide Fumes, Zinc Oxide Fumes, and Copper Fumes. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Aspen Equipment CO.
View Aspen Equipment CO.'s full OSHA safety record →
More inspections in this industry (NAICS 423810)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340441013.