Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPA DOORS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPA DOORS, INC in 1732 UNIVERSAL CITY BLVD, UNIVERSAL CITY, TX 78148 (NAICS 321911). OSHA activity number 340442094.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Supa Doors, INC — free Get an email when a new federal OSHA severe-injury report for Supa Doors, INC is published. One employer, no account, unsubscribe in one click.
Establishment
SUPA DOORS, INC
Site address
1732 UNIVERSAL CITY BLVD
City
UNIVERSAL CITY
State
TX
ZIP
78148
Mailing
1732 UNIVERSAL CITY BLVD, UNIVERSAL CITY, TX 78148
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
157
Ownership type
A

5 citations on file for this inspection.

1910.213 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 10, 2015
Abate by
Jul 30, 2015
Penalty
Initial $3,600 · Current $1,260 Reduced
29 CFR 1910.213(d)(1): Each circular crosscut table saw was not guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws:     Custom door frame area, north: On or about March 4, 2015, and at times prior thereto, employees were exposed to a caught by hazard, while using a table saw that did not have a guard to protect the employees from the exposed cutting blade.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $3600

1910.213 M01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 10, 2015
Abate by
Jul 30, 2015
Penalty
Initial $6,300 · Current $2,205 Reduced
29 CFR 1910.213(m)(1): Cutting heads of hand fed panel raiser were not enclosed with a cage or adjustable guard so designed so as to keep the operator's hand away from the cutting edge:     Special factory shaper area, Shaper # 2: On or about March 4, 2015, and at times prior thereto, employees were exposed to a caught by hazard, while using a Casolin shaper that did not have a guard to protect the employees from the exposed cutting head.
Recent events (2)
  • — I (S) $2205
  • — Z (S) $6300

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 10, 2015
Abate by
Jul 30, 2015
Penalty
Initial $3,600 · Current $1,260 Reduced
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  Special factory shaper area, Shaper # 2: On or about March 4, 2015, and at times prior thereto, employees were exposed to a pinch point hazard, while operating a Casolin shaper that did not have a guard for the exposed 1/2 inch v-belt that rotates the cutting head.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $3600

1910.303 G01 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 10, 2015
Penalty
Initial $3,600 · Current $1,260 Reduced
29 CFR 1910.303(g)(1)(i)(A): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:     Special factory shaper area, north: On or about March 4, 2015, and at times prior thereto, employees were exposed to an electrical hazard, while using shapers that did not have a unobstructed access to the electrical safety switch and the 480volt transformer in the event of an emergency.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $3600

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Jul 30, 2015
Penalty
Initial $2,700 · Current $945 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were used as a substitute for the fixed wiring of a structure:     CSD Kit area, computer desk: On or about March 4, 2015, and at times prior thereto, an employee was exposed to an electrical hazard, while working on his computer setup that was that was receiving power from a 120 volt extension cord that was permanently attached to the building structure.
Recent events (2)
  • — I (S) $945
  • — Z (S) $2700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340442094.