UNIVERSAL CITY, TX —
OSHA Inspection: SUPA DOORS, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUPA DOORS, INC in 1732 UNIVERSAL CITY BLVD, UNIVERSAL CITY, TX 78148 (NAICS 321911). OSHA activity number 340442094.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPA DOORS, INC
- Site address
- 1732 UNIVERSAL CITY BLVD
- City
- UNIVERSAL CITY
- State
- TX
- ZIP
- 78148
- Mailing
- 1732 UNIVERSAL CITY BLVD, UNIVERSAL CITY, TX 78148
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 157
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.213 D01
- Issued
- Jul 10, 2015
- Abate by
- Jul 30, 2015
- Penalty
- Initial $3,600 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Each circular crosscut table saw was not guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws: Custom door frame area, north: On or about March 4, 2015, and at times prior thereto, employees were exposed to a caught by hazard, while using a table saw that did not have a guard to protect the employees from the exposed cutting blade.
Recent events (2)
- — I (S) $1260
- — Z (S) $3600
1910.213 M01
- Issued
- Jul 10, 2015
- Abate by
- Jul 30, 2015
- Penalty
- Initial $6,300 · Current $2,205 Reduced
General-duty citation text
29 CFR 1910.213(m)(1): Cutting heads of hand fed panel raiser were not enclosed with a cage or adjustable guard so designed so as to keep the operator's hand away from the cutting edge: Special factory shaper area, Shaper # 2: On or about March 4, 2015, and at times prior thereto, employees were exposed to a caught by hazard, while using a Casolin shaper that did not have a guard to protect the employees from the exposed cutting head.
Recent events (2)
- — I (S) $2205
- — Z (S) $6300
1910.219 E01 I
- Issued
- Jul 10, 2015
- Abate by
- Jul 30, 2015
- Penalty
- Initial $3,600 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): Special factory shaper area, Shaper # 2: On or about March 4, 2015, and at times prior thereto, employees were exposed to a pinch point hazard, while operating a Casolin shaper that did not have a guard for the exposed 1/2 inch v-belt that rotates the cutting head.
Recent events (2)
- — I (S) $1260
- — Z (S) $3600
1910.303 G01 I A
- Issued
- Jul 10, 2015
- Penalty
- Initial $3,600 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1: Special factory shaper area, north: On or about March 4, 2015, and at times prior thereto, employees were exposed to an electrical hazard, while using shapers that did not have a unobstructed access to the electrical safety switch and the 480volt transformer in the event of an emergency.
Recent events (2)
- — I (S) $1260
- — Z (S) $3600
1910.305 G01 IV A
- Issued
- Jul 10, 2015
- Abate by
- Jul 30, 2015
- Penalty
- Initial $2,700 · Current $945 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were used as a substitute for the fixed wiring of a structure: CSD Kit area, computer desk: On or about March 4, 2015, and at times prior thereto, an employee was exposed to an electrical hazard, while working on his computer setup that was that was receiving power from a 120 volt extension cord that was permanently attached to the building structure.
Recent events (2)
- — I (S) $945
- — Z (S) $2700
More inspections in this industry (NAICS 321911)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340442094.