CORNING, NY —
OSHA Inspection: H.B.D. REALTY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of H.B.D. REALTY INC. in 147 PINE STREET, CORNING, NY 14830 (NAICS 238190). OSHA activity number 340442516.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H.B.D. REALTY INC.
- Site address
- 147 PINE STREET
- City
- CORNING
- State
- NY
- ZIP
- 14830
- Mailing
- 22 WEST MARKET STREET, CORNING, NY 14830
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.304 I01
- Issued
- Mar 20, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) At the jobsite, on the first floor, on or about 3/4/15: Employees were rip-cutting material on a table saw without the blade being guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1926.403 B01 I
- Issued
- Mar 20, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,400 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, on the 3rd floor, on or about 3/4/15: An employee back fed a circuit by inserting conductive bare wire into the female end of an extension cord that was powered by the temporary service. b) At the jobsite, on the 1st floor, on or about 3/4/15: Employees were working and transiting the stairwell to the upper floors where a box fan designed for household purposes had been installed and used to move warm air upstairs. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2400
1926.403 I02 I
- Issued
- Mar 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, on the first floor, on or about 3/4/15: Employees were working in close proximity to a temporary space heater where a panel cover was removed, exposing workers to live electrical parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 I
- Issued
- Mar 20, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the opening. a) At the jobsite, on the 1st floor, on or about 3/4/15: Employees were working in close proximity to an elevator shaft where sheet product was placed over rebar that provided partial cover to the lower level approximately 8 feet below (basement). Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1926.502 B02 I
- Issued
- Mar 20, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(2)(i): Midrails, when used, were not installed at a height midway between the top edge of the guardrail system and the walking/working level: a) At the jobsite, on the 3rd floor, on or about 3/4/15: Employees were working in close proximity to an elevator shaft where no mid-rail was installed to secure access to an elevator shaft and falls to the lower level approximately 10 feet below. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340442516.