Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STAUFFER LAWN & LANDSCAPE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STAUFFER LAWN & LANDSCAPE, LLC in 1150 WASHINGTON STREET, AUBURN, KS 66402 (NAICS 561730). OSHA activity number 340445022.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stauffer Lawn & Landscape, LLC — free Get an email when a new federal OSHA severe-injury report for Stauffer Lawn & Landscape, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1150 WASHINGTON STREET
City
AUBURN
State
KS
ZIP
66402
Mailing
1150 WASHINGTON STREET, AUBURN, KS 66402
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
7
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2015
Abate by
May 20, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to flying plastic projectile hazards due to possible mechanical failure of the plastic, polyvinyl chloride (PVC), piping system used to transport compress air:  Employees engaged in landscaping activities in the shop were exposed to the hazards of flying shrapnel from an exploding plastic PVC pipe.  Schedule 40 PVC pipe was used to transport compressed air in the shop area of the facility.  Steel piping ran from the air compressor across the wall, then PVC piping up to the ceiling, across and down beside the garage door. The compressed air was at an operating pressure of approximately 100 pounds per square inch (PSI).   Among other methods, the following are feasible and acceptable methods to correct the hazard:      1.  Replace the current PVC compressed air piping system with materials suitable for the maximum air pressure as recommended by the Plastic Pipe Institute, such as ABS or metal.      2.  Follow the American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.1-2007, Power Piping, as applicable.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.303 B07 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2015
Abate by
May 20, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.   Employees engaged in equipment maintenance activities in the shop were exposed to electrical shock and fire hazards in that an unused opening in the electrical panel box, located on the southwest wall of the shop was not covered.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 3, 2015
Abate by
May 20, 2015
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Employees engaged in equipment maintenance activities in the shop were exposed to electrical shock and fire hazards in that circuit breakers were not marked or labeled in the electrical panel box, located on the southwest wall of the shop.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2015
Abate by
May 20, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  Employees engaged in welding activities in the shop area were exposed to an electrical shock hazard in that the flexible cord supplying power to the Miller, Millermatic 212 electric welder, was not equipped with strain relief. The conductors on both ends of the extension cord providing 220 VAC power had pulled free from the plug.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

View Stauffer Lawn & Landscape, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340445022.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.